IDP 800 Terminal Series - Hardware Guide
T209, Version 01 58 © SkyWave Proprietary
7.
Wrap the mating connector with waterproof sealing tape if using the connector in
changing weather conditions.
4.8.2 Protect the Cables and Cable Connectors
CAUTION
Cable management and connector strain relief must be
incorporated in the installation. SkyWave highly recommends
securing the cable at regular intervals along its length as part of
the installation to prevent cable wear and eliminate strain on the
terminal connector. Damage to the terminal connector interface
or cable may contribute to hardware failure.
To protect the terminal's connector interface, follow the guidelines below:
Apply tape around the cable ends to help in routing the cable.
Secure the cable such that it does not pull on the connector or strain the terminal
connector.
Tie the cable down so that the weight of a vibrating cable will not stress or strain
the connection.
Tie the cable down using cable ties and tie holders (Figure 47) at 300 to 600 mm
intervals along the cable route to prevent chafing, wear, or strain.
Secure the cable tie holder with a self-tapping screw (Figure 47) for best holder
retention.
Figure 47 Cable Management
4.9 Apply Power
4.9.1 Power on the Battery Terminal
By default the terminal automatically powers on when the batteries or an external power
source are applied.
4.9.2 Connect to External Power (optional)
CAUTION
Apply power only after
making ground
connection.
Adhesive cable tie
holder. Apply a self-
tapping screw here
for added strength.