![Skytrac ISAT-100 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/skytrac/isat-100/isat-100_operating-instructions-and-installation-manual_1291738030.webp)
SkyTrac Systems Ltd.
Document Rev. 02.010
ISAT-100-OPD-SOI
Page 23 of 26
Restricted Proprietary and Confidential Information
5 M
AINTENANCE AND
C
ONTINUED
A
IRWORTHINESS
5.1 Continued Airworthiness
The ISAT-100 does not require any maintenance if installed in an actively flying
aircraft, other than the battery replacement as per note below.
NOTE:
Batteries are subject to lifespan restrictions of up to 5 years. The built-in
sealed lead-acid battery must be replaced by SkyTrac Systems after
five (5) years. This includes the time the ISAT spent sitting on a shelf
while not installed in an actively flying aircraft. If the ISAT-100 is not
installed in an actively flying aircraft for a period of time that is greater
than 3 months, apply 28 Volts to System connector for six (6) hours to
maintain battery charge.
Periodic inspection is required as follows:
•
Operator is to inspect the Mains Power breaker once every six months
to verify proper operation of the breaker.
•
Operator is to inspect the ISAT-100 LED’s once every six months to
verify proper operation of the ISAT-100 charging circuit.
5.2 Maintenance Instructions
With the exception of the backup lead-acid battery (see maintenance details in section 6.1
above), the ISAT-100 does not require any maintenance.
The document reference is online, please check the correspondence between the online documentation and the printed version.