INSTALLING THE ON/OFF SOLENOID
1. Remove the two screws from the front metal faceplate on the AF-LMF valve box and set the face plate aside.
2. Take a screwdriver (flat head), and remove the aluminum valve cap fitting.
3. Take the ON/OFF solenoid and install it in to the threaded hole where the brass cap fitting was. Do not overtighten.
4. Replace the metal faceplate on the front of the valve. Make sure that the red and black wires on the solenoid can reach out the
back of the metal box, so that they can connect to the receiver.
NOTE: KEEP THE VALVE CAP FITTING. IF THE SOLENOID IS REMOVED, THE CAP WILL NEED TO BE REPLACED.
Brass Cap
Fitting
Standard
Screwdriver
AFLMF
Valve Assembly
ON/OFF
Solenoid
Standard
Screwdriver
AFLMF
Valve Assembly
CONNECTING THE RECEIVER TO THE AF-LMF VALVE KIT
1. Connect the Black wire on the receiver with the Black wire on the solenoid.
2. Connect the Red wire on the receiver with the Red wire on the solenoid.
3. After the wires are securely connected, put the receiver shield on the receiver and place it where ambient temperatures do not
exceed 130º F.
NOTE:
The colors of the wires must match, if they do not, the functions of the receiver will not work.
Remote Receiver
REMOTE
OFF
PULSE MODE
Terminals
BLACK Wire
(Female)
RED Wire
(Female)
LEARN
ADJ.
BLACK Wire
(Male)
RED Wire
(Male)
LEARNING TRANSMITTER TO RECEIVER
This transmitter has one of 1,048,576 unique security codes. It may be necessary to program the remote receiver to learn the security
code of the transmitter upon initial use, if batteries are replaced, or if using a replacement transmitter.
•
Make sure the receiver’s slide switch is in the
REMOTE
position.
•
Press and release the
LEARN
button on the receiver.
•
When you hear the “Beep”, press and hold the
ON
or
OFF
button for about 2 seconds on the transmitter.
•
You will then hear a series of “rapid” beeps that indicate your new transmitter has been accepted by the receiver.
REV. 5-16-16 Page 3
Skytech: RCAF-LMF/RD
www.FireplaceRemoteControls.com