Skytech RCAF-LMF/RD Скачать руководство пользователя страница 2

This remote control includes a childproof “LOCK-OUT” feature that allows the user to “lock-out” operations from the transmitters.

• 

To activate the “LOCK-OUT” feature, press and hold the 

ON

 and 

OFF

 icons on the 

LCD screen together, for 5 seconds.  The lock icon will appear on the LCD screen.

• 

To disengage the “LOCK-OUT”, press and hold the 

ON

 and 

OFF

 icons on the LCD 

screen together, for 5 seconds.  The lock icon will disappear on the LCD screen.

NOTE:

 If the appliance is already operating in the ON mode engaging the “LOCK-OUT” 

will not cancel the operating mode.

CHILDPROOF “LOCK-OUT”

OFF

ON

RECEIVER

Install the (4) AA-size batteries supplied with the unit. It is recommended that ALKALINE batteries always be used for this product. 

Be 

sure the batteries are installed with the (+) and (-) ends facing the correct direction.

•  REMOTE

: will allow use of handheld transmitter. If the system does not respond 

to the transmitter on initial use, check the battery positions in the remote. If that 

does not work, see the LEARNING TRANSMITTER TO RECEIVER section. 

•  OFF

: will disable the remote receiver.

•  It is suggested that the slide switch be placed in the OFF position if you will 

be away from your home for an extended period of time. 

The remote receiver has a 2-position slide switch for selecting the mode of operation 

REMOTE/OFF

WARNING

This remote control system must be installed exactly as outlined in these instructions.  Read all instructions completely before at-

tempting installation.  Follow instructions carefully during installation.  Any modifications of this remote control or any of its compo-

nents will void the warranty and may pose a fire hazard.

Do not connect any gas valve or electronic module directly to 110-120VAC power.  Consult gas appliance manufacturer’s instruc-

tions and wiring schematics for proper placement of all wires.  All electronic modules are to be wired to manufacturer’s specifica-

tions.

The following wiring diagrams are for illustration purpose only.  Follow instructions from manufacturer of gas valve and/or electronic 

module for correct wiring procedures.  Improper installation of electric components can cause damage to electronic module, gas 

valve and remote receiver.  

INSTALLATION

The remote receiver should be placed on or near the fireplace hearth. The remote receiver should be kept away from temperatures 

exceeding 130º F.  Battery life is also significantly shortened if batteries are exposed to temperatures 130ºF or higher.

Before installation make sure the remote receiver slide switch is in the 

OFF

 position. After installation be sure that the slide switch is 

moved to the 

REMOTE

 position.

HEARTH MOUNT

• 

The remote receiver can be placed on the fireplace hearth or under the fire-

place behind the control access panel. 

• 

Use the wires attached to the remote receiver to connect to the gas valve or 

the electric module (Female spade connectors are provided).

REMOTE

LEARN

Requires 4-AA 1.5V

alkaline batteries

Learning

 button

Remote Receiver

Batt

ery c

over

 slide

s on

/off

Slide

Switch

REMOTE

OFF

OF

F

REV. 5-16-16 Page 2

Skytech: RCAF-LMF/RD

www.FireplaceRemoteControls.com

1.888.977.6849

Содержание RCAF-LMF/RD

Страница 1: ...k light will light up and stay on for 5 seconds Touch the ON button on the LCD screen to turn the appliance on The flame icon will appear on the LCD screen OFF OPERATION Touch the OFF button on the LCD screen to turn the appliance off The flame icon will disappear from the LCD screen SETTING FAHRENHEIT CELSIUS SCALE The factory setting for temperature is ºF To change this setting to ºC press and h...

Страница 2: ...installation Follow instructions carefully during installation Any modifications of this remote control or any of its compo nents will void the warranty and may pose a fire hazard Do not connect any gas valve or electronic module directly to 110 120VAC power Consult gas appliance manufacturer s instruc tions and wiring schematics for proper placement of all wires All electronic modules are to be w...

Страница 3: ...receiver with the Red wire on the solenoid 3 After the wires are securely connected put the receiver shield on the receiver and place it where ambient temperatures do not exceed 130º F NOTE The colors of the wires must match if they do not the functions of the receiver will not work Remote Receiver REMOTE OFF PULSE MODE Terminals BLACK Wire Female RED Wire Female LEARN ADJ BLACK Wire Male RED Wire...

Страница 4: ...re fully charged Check batteries in transmitter to make sure contacts are touching and ends of battery Bend metal contacts in for tighter fit Ensure receiver and transmitter is within 20 to 25 foot operating range Keep receiver from temperatures exceeding 130º F Battery life will be shortened if exposed to high temperatures If receiver is installed in a tightly enclosed metal surrounding the opera...

Отзывы: