Rev
.
7/10/15 Page 2 of 5
Skytech RCAF-LMF-1
3.
Install the ON/OFF solenoid into the threaded hole on the AF-LMF that the brass cap fitting was removed from and screw
into place and do not over tighten. NOTE: Figure 2
4.
Replace the AF-LMF front faceplate and reinstall the (2) screws and tighten.
5.
Make sure to locate the RED & BLACK wires so they come out the back of the AF-LMF to connect to the receiver.
Figure #1
Figure #2
WIRING INSTRUCTIONS
CONNECTING THE RECEIVER TO THE AF-LMF VALVE KIT WITH THE LATCHING SOLENOID
1. Connect the BLACK 18 gauge stranded wire with the 1/4’ female terminal from the receiver to the BLACK wire with the 1/4” male
terminals from the valve solenoid.
2. Connect the RED 18 gauge stranded wire with the 1/4’ female terminal from the receiver to the RED wire with the 1/4” male
terminals from the valve solenoid.
3. After receiver wires are connected to the valve solenoid wire make sure the receiver shield is located over the receiver and then
locate the receiver in an area that will not exceed the 130° F. This location will always be away from the AF-LMF towards the front
of the firebox.
IMPORTANT NOTE:
Operation of these controls is dependent on which wire is attached to which terminal. If operation of control
does not correspond to operating buttons on transmitter, reverse wire installation at the receiver or at the control.
NOTE
: Up to 6.3 VDC of power is provided at the receiver terminal.
www.FireplaceRemoteControls.com