MANUAL CHECK OF “SWING” OR TEMPERATURE DIFFERENTIAL 

The operation of the factory set “THERMO SWING” can be checked by adjusting the SET TEMP 2 

0

F above or below the room 

temperature. This will cause the system to turn ON or OFF. Normally the system will only respond to temperature changes every two 
minutes. Manually  changing the SET temperature will activate the system in less than 10 seconds. If the “SWING” is changed, then 
anew room temperature differential will respond. Factory setting of SWING temperature is 2 

0

F. 

 
1. 

To change the temperature “SWING” setting (1-3), press the AHEAD +  BACK buttons simultaneously to display the current “SWING” 
setting in the SET TEMP frame.  The word SWING will display on the LCD screen. 

2. 

Press the UP or DOWN button to change the temperature differential or “SWING” (1-3).  See above for 1-3 “SWING” temperature 
values.  

3. 

To store the “swing number”, press the SET/RETURN button or allow 15 seconds to lapse, and the new “swing number” will be 
automatically programmed. 

 

NOTE: When the gas fireplace system is activated, a FLAME icon will display on the LCD screen indicating a signal has been sent from 
the TRANSMITTER. 

 

OPERATING INSTRUCTIONS 

 

THERMO OPERATION 

– (Systems operates thermostatically based on SET TEMP setting, ONLY)

 

 

 
SETTING DESIRED ROOM TEMPERATURE 

 

This remote control system can be thermostatically controlled when the 
transmitter is in the THERMO mode (THERMO must be displayed on the 
screen). 

 

1. 

To set the DESIRED room temperature, press the MODE button to place the 
transmitter into THERMO mode.  THERMO ON or OFF will display. 

2. 

Then press the UP or DOWN button to select the DESIRED room 
temperature.  The highest SET temperature is 99 

0

 F (32 

0

C).  The lowest 

SET temperature is 45 

0

 F (6 

0

C). 

3. 

The TRANSMITTER will “sense” the room temperature every two minutes 
automatically turning the fireplace ON or OFF thermostatically. 

 

MANUAL CHECK OF THERMO OPERATION 
 

The operation of the Thermo setting can be checked on demand by adjusting the SET temperature 2 

F above or below the room temperature, 

which will cause the system to turn ON or OFF, respectively.  Normally, however, the system will only respond to temperature changes every 
two minutes.  NOTE:  if “SWING” number has been changed, then activation will occur at the new “SWING” setting.   
 

 
TEMPERATURE OVERRIDE 

– (Operates only in PROGRAM mode) 

 

The user may change the current SET temperature without changing the 
programs stored in the transmitter’s memory.  The OVERRIDE feature will be 
automatically cancelled at the start of the next PROGRAM PERIOD. 

 

1. 

To change current SET TEMP, press the UP or DOWN  button.  (Setting will  
be cancelled automatically when next program period begins.)  The  
word OVERRIDE will appear over the SET frame on the LCD. 

2. 

To cancel temperature OVERRIDE, press SET button. 

 
 
 

TEMPERATURE HOLD

 – (Operates only in PROGRAM mode.) 

 

The user may override the SET temperature during any period, adjusting the 
SET temperature to a CONSTANT new SET/HOLD temperature. 

 

1. 

Press the UP or DOWN button to change the SET temperature to the level 
desired.  The word OVERRIDE will appear in SET frame on the LCD. 

2. 

To HOLD the new temperature at a CONSTANT setting, push the UP and 
DOWN buttons TOGETHER to activate the HOLD function.  The word HOLD 
will appear over the SET frame and the word OVERRIDE will disappear. 

3. 

To cancel OVERRIDE or HOLD, press the SET button. 

 

1

MO

EVE

ON

THERMO

2

TEMP

FLAME

SET

FAN

O F F

O F F

UP

DOWN

MODE

TIMER

 TIME

SET

PROG

AHEAD

BACK

FAN

 

2

1

TEMP

SET

MO

DAY

PROGRAM

OVERRIDE

ON

FLAME

FAN

OFF

UP

DOWN

MODE

TIMER

 TIME

SET

PROG

AHEAD

BACK

FAN

 

3

1,2

TEMP

SET

MO

DAY

PROGRAM

HOLD

ON

FLAME

FAN

OFF

UP

DOWN

MODE

TIMER

 TIME

SET

PROG

AHEAD

BACK

FAN

 

Содержание 3301PF

Страница 1: ...turned off THERMO indicates the system will automatically cycle ON OFF depending on programmed SET temperature PROGRAM indicates the system is operating with PROGRAMMED settings 5 START AT Flashes wh...

Страница 2: ...RENT TIME OF DAY Hours and minutes To program settings first remove the battery cover on the back of the transmitter If you have not already installed the 2 AAA batteries this would be a good time to...

Страница 3: ...temperature programs to suit their personal schedule Each day is divided into four periods MORNING DAY EVENING AND NIGHT A blank programming chart is provided below to record your customized time and...

Страница 4: ...OMIZED program that you have entered and return to the FACTORY program you may do so To cancel a CUSTOMIZED program 1 Press the SET button to make sure the LCD screen is in normal state 2 Then press a...

Страница 5: ...is 45 0 F 6 0 C 3 The TRANSMITTER will sense the room temperature every two minutes automatically turning the fireplace ON or OFF thermostatically MANUAL CHECK OF THERMO OPERATION The operation of the...

Страница 6: ...has expired OPERATING FAN Operates only in ON THERMO PROGRAM MODES This remote control system has the capability of operating a 110 VAC fan or blower system that may be included with your gas applianc...

Страница 7: ...ace will begin operating again However the beeping will continue if the ambient temperature remains between 120 0 F and 130 0 F This beeping alerts the user that the RECEIVER should be repositioned so...

Страница 8: ...h the National Electric Code ANSI NFPA No 70 current in the United States or with current CSA C22 1 Canadian Code in Canada WARNING DO NOT CONNECT 110 120 VAC WIRING TO THE GAS CONTROL VALVE OF THIS A...

Страница 9: ...lve It does not matter which wires go to which set of terminals at the receiver or at the gas valve This is a DRY CONTACT circuit and no power is provided to these terminals by the remote receiver Ope...

Страница 10: ...ding wire to the 1 4 terminal on the remote receiver You may also attach the grounding wire under the grounding screw SYSTEM CHECK MILLIVOLT VALVES Light your gas appliance following the lighting inst...

Страница 11: ...initial use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory When matching security codes be sure slide button on the receiver is in the REMOTE p...

Страница 12: ...sure the transmitter is communicating with the receiver If the receiver beeps when the MODE button is depressed on the transmitter they are communicating If the receiver does not beep when the MODE b...

Страница 13: ...ing with PROGRAMED settings OTHER OPERATIONS Press corresponding buttons on TRANSMITTER to activate functions 1 TIME OF DAY Press TIMER TIME button for less than ONE second 2 TIMER OPERATION Press and...

Страница 14: ...button 7 Again press PROG button The next PERIOD and DAY will begin to flash 8 Repeat steps 2 through 7 for all 7 DAYS until each PERIOD OF DAY is programmed 9 When all programmed settings are comple...

Отзывы: