Model: 3003P
REV. 12-7-12 Page 12
1.
To change the temperature “SWING” setting (1-3), press the
AHEAD & BACK buttons “
simultaneously”
to display the current
“SWING”
2.
Setting in the SET TEMP frame. The word SWING will display
on the LCD screen.
3.
Press the UP or DOWN button to change the temperature
differential or “SWING” (1-3). See above for 1-3 “SWING” tem
perature values.
4.
To store the “swing number”, press the SET button or allow 15
seconds to lapse, and the new “swing number” will be
automatically programmed.
Fig. 31 Setting Swing Temp
MANUAL CHECK OF “SWING” OR TEMPERATURE DIFFERENTIAL
The operation of the factory set “THERMO SWING” can be checked by adjusting the SET TEMP 2°F above or below the
room temperature. This will cause the system to turn ON or OFF. Normally the system will only respond to temperature
changes every two minutes. Manually changing the SET temperature will activate the system in less than 10 seconds. If
the “SWING” is changed, then a new room temperature differential will respond. Factory setting of SWING temperature is
2°F.
OPERATIONAL NOTE:
TO CONSERVE BATTERY POWER, CHANGES IN TEMPERATURE ARE ONLY RECORDED
EVERY TWO MINUTES. Additionally, to prevent repeated thermo-cycling of gas appliance, the sensing unit in the
transmitter will only activate the remote receiver when temperature change exceeds 2°F (1°C) above or below the
SET (desired) temperature. However, if the “SWING” setting has been changed from the factory setting (2°F /1°C),
then thermo-cycling will activate at the new setting of the “SWING” number.
CHILDPROOF “LOCK –OUT” – (CP)
This remote control includes a CHILDPROOF(
CP
) “LOCK-OUT” feature that allows the user to disable the operation of
the fireplace from the TRANSMITTER when any button is pressed.
SETTING “LOCK-OUT” – (CP)
1. To activate the “LOCK-OUT” feature, press and hold the
UP and TIMER/TIME buttons, together, for 5 seconds. The
letters
CP
will appear in the TEMP frame on the LCD screen.
2. To disengage the “LOCK-OUT”, press and hold the UP
and TIMER/TIME buttons, together for 5 seconds or more,
and the letters
CP
will disappear from the LCD screen and the
transmitter will return to its normal operating condition.
NOTE:
If the fireplace system is already operating in the ON, THERMO or PROGRAM MODES, engaging the “LOCK-
OUT” will not cancel the operating MODE. Engaging the “LOCK-OUT” prevents only the manual operation of the TRANS-
MITTER. If in the auto modes, the THERMO and/or PROGRAM operation will continue to operate normally. To totally
“LOCK-OUT” the operation of the TRANSMITTER’S operating signals, the transmitter’s MODE must be set to OFF.
AHEAD
TIMER
PROG
TIME
UP
MODE
DOWN
BA
CK
SE
T
AHEAD
TIMER
PROG
TIME
UP
MODE
DOWN
BA
CK
SE
T