CHECKING THERMO OPERATION
The operation of the Thermo setting can be checked on demand by adjusting the SET temperature 2°F above or below the
room temperature, which will cause the system to turn ON or OFF, respectively. Normally, however, the system will only
respond to temperature changes every two minutes. NOTE: If “SWING” number has been changed, then activation will
occur at the new “SWING” setting. See pages 11 and 12 for more temperature SWING information.
When the gas fireplace system is activated, a FLAME icon will display on the LCD screen indicating a signal has been sent
from the transmitter.
THERMO MODE OPERATION
(System operates as a thermostat based on the SET temperature only)
SETTING DESIRED ROOM TEMPERATURE
This remote control system can be thermostatically controlled
when the transmitter is in the THERMO mode.
1. To set the DESIRED room temperature, press the MODE
button on the transmitter until the word THERMO is visible on
the LCD screen. The larger number in the center of the screen
is the room temperature and the smaller number on the right
side is the SET temperature.
.
2. Press the UP or DOWN button to select the DESIRED room temperature. The highest SET temperature is 99°F
(32°C). The lowest SET temperature is 45°F (6°C).
3. The TRANSMITTER will monitor the room temperature every 2 minutes automatically turning fireplace ON or OFF
thermostatically.
SET TEMPERATURE OVERRIDE
– (PROGRAM mode only)
The user may change the current SET temperature without chang-
ing the programs stored in the transmitter’s memory. The OVER-
RIDE feature will be automatically cancelled at the start of the next
PROGRAM PERIOD.
1. To change current SET TEMPERATURE, press the UP or
DOWN button (Setting will be cancelled automatically when next
program period begins.) The word OVERRIDE will appear over
the SET frame on the LCD screen.
2. To cancel temperature OVERRIDE, press SET button.
SET TEMPERATURE HOLD
– (PROGRAM mode only)
The user may override the SET temperature during any period,
adjusting the SET temperature to a CONSTANT new SET/HOLD
temperature.
1. Press the UP or DOWN button to change the SET temperature
to the level desired. The word OVERRIDE will appear in SET
frame on the LCD.
2. To HOLD the new temperature at a CONSTANT setting, push the
UP and DOWN buttons “
at the same time”
to activate the HOLD
function. The word HOLD will appear over the SET frame and the word OVERRIDE will disappear.
3. To cancel OVERRIDE or HOLD, press the SET button.
TRANSMITTER OPERATING MODES
Fig. 25 Thermo on Mode
AHEAD
TIMER
PROG
TIME
UP
MODE
DOWN
BA
CK
SE
T
Fig. 26 SET Temperature Override
AHEAD
TIMER
PROG
TIME
UP
MODE
DOWN
BA
CK
SE
T
Fig. 27 Set Temperature Hold
AHEAD
TIMER
PROG
TIME
UP
MODE
DOWN
BA
CK
SE
T