Skypatrol SP9600 Скачать руководство пользователя страница 3

SP9600 User Manual 

 

 

Attention 

 

All  wireless  data  transferring  trackers  produce  interference  that  may  affect  other 
trackers which are placed nearby. 

 

The tracker may be connected only by qualified individuals. 

 

The tracker must be firmly fastened in the predefined location. 

 

Changes  or  modifications  not  expressly  approved  by  the  party  responsible  for 
compliance could void the user’s authority to operate the equipment. 

 

This  equipment  generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not 
installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. 

 
Instructions Of Safety 

 

By  following  these  requirements  and  recommendations  you  will  avoid  dangerous 
situations.  You  must  read  these  instructions  carefully  and  follow  the  strictly  before 
operating the tracker! 

 

Please install the batteries carefully according this user manual indicates to avoid short 
circuit that may causes malfunction of tracker. 

 

Before usage, the tracker should be placed so that its LED indicators are visible, which 
show what status of operation the tracker is in. 

 

When connecting the connection cables to the vehicle, the appropriate jumpers of the 
power supply of the vehicle are recommended to be disconnected. 

 

Before dismounting the tracker from the vehicle, the connection must be disconnected. 

 

Copyright and Disclaimer 

The User Manual may be changed without notice. 

Without prior written approval of Skypatrol LLC., this User Manual, or any  part thereof, 
may not be reproduced for any purpose whatsoever, or transmitted in any form, either 
electronically or mechanically, including photocopying and recording. 
Skypatrol LLC. shall not be liable for direct, indirect, special, incidental, or consequential 
damages  (including  but  not  limited  to  economic  losses,  personal    injuries  and  loss  of 
assets  and  property)  caused  by  the  use,  inability,  or  illegality  to    use  the  product  or 
documentation. 

Содержание SP9600

Страница 1: ...SP9600 User Manual 1 Skypatrol SP9600 User Manual v2 0 Copyright 2017 Skypatrol...

Страница 2: ...Manual 2 Document History File name SP9600 user manual Created By Hanson Product SP9600 Creation date 2016 01 15 Version V2 0 Update date 2016 02 24 Status Release Reviewed By Update History NO Updat...

Страница 3: ...lly according this user manual indicates to avoid short circuit that may causes malfunction of tracker Before usage the tracker should be placed so that its LED indicators are visible which show what...

Страница 4: ...LED indicator behavior 10 4 Device installing way 12 4 1 Dismount 12 4 2 Configure device 15 4 3 Install magnet 16 4 4 Connect battery packet 17 4 5 Dismantle battery packet 17 4 6 Charging device 18...

Страница 5: ...Interval To GRPS Server 27 5 9 Set device dismantled alarm 28 5 10 Set product firmware upgrade 29 6 User Combine Command 30 6 1 Command Error SMS 30 6 2 Command Success SMS 30 7 SMS Report Explanatio...

Страница 6: ...ay of dual users can be configured flexibly Set time distance angle event and dynamic upload Flexibly configure single event comb events 28 polygons and 128 Geo fence can relate to speed time and leve...

Страница 7: ...IP 7 Shock impact MIL STD 810 SAE J1455 USB Normal 4Pin socket on PCB space 1 25MM CPU ARM EFM32GG330F512 QFN64 9x9 Silicon Bluetooth 4 0 Power External Battery packet AC adapter Internal Rechargeable...

Страница 8: ...overview 3 1 Check Part List Before starting check and make sure the following items have been included with your device If anything is missing please contact your supplier Standard Part List Main un...

Страница 9: ...SP9600 User Manual 9 Optional Part List USB cable IO cable Charger Magnet Screw battery packet Bluetooth adapter...

Страница 10: ...SP9600 User Manual 10 3 2 Product indicator diagram Charging LED indicator GPS LED indicator System LED indicator GSM LED indicator Battery packet connector or IO data connector Light sensation area...

Страница 11: ...finition Interface definitions are as below Pin Name Definition 1 VCC DC5V input battery packet supply or charger to input 2 AD1 Battery packet detection 3 IN OUT1 General bidirectional input output 4...

Страница 12: ...m deployment and external battery pack supported Built in 3 axis G sensorfor motion detection Light sensor for tracker removing alarm GSM jamming detection Dynamic report interval according topreset c...

Страница 13: ...nstantly via GPRS SMS channel according to setting Note Above events by default are disabled please enable them by configuration tool if necessary or contact your distributor forfurther information re...

Страница 14: ...User Manual 14 c Open Card slot d Install SIM card e Close card slot f Be sure to plug in the power line at first time use g Connect USB cable and use configuration tool to configure device h Screw c...

Страница 15: ...Device driver file Gosafe Cdc b Open the configuration tool by double click Configuration Tool Note if there is an error or you are unable to open the file please install Microsoft NET Framework 4 0...

Страница 16: ...ect the device to your computer Choose the correct serial port and device mode then click connect d Input your desired parameters and click write to write all of the data to device 4 3 Install magnet...

Страница 17: ...onnect battery packet a Connect b Close c Fasten 4 5 Dismantle battery packet Use tweezers or other tools to insert and press down the point showed on the picture at the same time open the buckle to d...

Страница 18: ...SP9600 User Manual 18 4 6 Charging device e Charging...

Страница 19: ...mmand User0 s factory default password is 1234 User1 s factory default password is also 1234 Command format 1 Set user0 phone number User0 Password UNO0 New phone number 2 Set user1 phone number User1...

Страница 20: ...scription New Password Fix 4 digits range is 0000 to 9999 Example Set user0 password 1234 UPW0 5678 5 3 Set ACK Command ACK command is used to set up UDP response mechanism switch Command format Disab...

Страница 21: ...rt mode0 It s called static mode 1 Report mode1 It s called dynamic mode This is valid only when command DNU is enabled Interval Report interval range is 30 to 900 seconds 15 to 59 minutes 1 to 720 ho...

Страница 22: ...SIM card is recognized it will fill in the APN automatically Example Set apn user name and password 1234 APN cmnet usr pw Query setting 1234 APN 5 6 Set GPRS Main Server Command SVR command is used to...

Страница 23: ...VR Query setting 1234 SVR 5 7 Set GPRS Backup Server Command BSV command is used to set GPRS backup server The device connects with the main server as priority When the connection between the device a...

Страница 24: ...socket 1234 BSV 114 142 154 28 3032 1 1 or 1234 BSV www anytracking net 3032 1 1 Delete main server 1234 BSV Query setting 1234 BSV 5 8 Set Position Report Interval To GRPS Server Command SVP command...

Страница 25: ...H Set dynamic report interval 1234 SVP 1 1H G H 5 9 Set device dismantled alarm Command SEN command can configure and query parameters that device is dismantled Format SEN interval checking time enabl...

Страница 26: ...multiple commands through an SMS message sent to the device The commands are separated by a comma The maximum length of the combined command is 256 bytes Format is as follows User name Separated Comm...

Страница 27: ...GSM 52dBm EXT_PWR 12 08V BAT 3 86V 301 Device name Firmware version Date Time Google map hyper link Event ID User defined event name Data GSM network signal strength External power voltage Built in b...

Страница 28: ...e Time Base station information type Main station MCC MNC Local area code Station ID Signal strength Neighbor station 1 Neighbor station 2 Event ID User defined event name GSM network signal strength...