![Skypatrol SP9600 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/skypatrol/sp9600/sp9600_user-manual_1291198025.webp)
25
SP9600 User
Manual
<Report mode>:
“O”: Disable
“G”: GPS information prior, otherwise use GSM tower position instead, GSM tower
uses HEX format.
“A”: GPS and GSM information
<Data format>:
“O”: Do not generate
data. “B”: HEX
“T”: text
Example:
Set static report
interval:
1234,SVP;0;30S;G;H
Set dynamic report interval:
1234,SVP;1;1H;G;H
5.9
Set device dismantled alarm
Command:
SEN command can configure and query parameters that device is dismantled.
Format :
SEN;<interval checking time>;<enable switch>
Parameter explanation:
< interval checking time >: each interval time to open the light
detection. Range:1-1800, unit: second
<enable switch>
:
“0”:turn off detection
“1”:turn on detection
Example:
Set to turn on detecting device dismantling alarm interval time
SEN;5;1