Water Points Connection
1 - The ovens must be connected to a cold water pipeline.
2 - Before turning on the hydraulic part, unload the water conductors of the building to
remove possible durt from the pipe.
3 - It is necessary to provide a ¾ screw for the meter to connect the hose to the water
entrance.
4 - Before turning on the hydraulic hose it is necessary to check the water exit according to
the recommendation of the table below.
5 - The new hose sets provided with appliance must be used and the old sets of hoses must
not be reused.
Switch and Eletric cables dimensions
1 - The switches must be exclusive to the appliance
2 - The wires dimensioning listed in the table below is for maximum length of 25 meters.
3 - The grounding is mandatory.
The Picture below indicates the external equipotential bonding system.
It must be used to guarantee that there is no potential difference between all the appliances
connected to the power grid, diminishing risks of electrical shock.
The different appliances must be turned on one to the other using their respective
equipotential bonding system.
45006.5
Switch and cables dimensions table
Model
Switch
Gauge wire
Maxiconv Oven
220 mono/biphasic
25 A
2,5 mm²
Содержание 67484.2
Страница 12: ...12 3 Operation 3 1 Activation 3 1 1 Oven Control Panel 09 08 03 05 10 01 07 02 04 06...
Страница 25: ...25 7 Electrical Diagram Oven With Vapour...
Страница 26: ...26 Steam Oven...
Страница 37: ...37 3 Operaci n 3 1 Accionamiento 3 1 1 Panel de Control del Horno 09 08 03 05 10 01 07 02 04 06...
Страница 49: ...49 7 Diagrama El ctrico Horno Sin Vapor...
Страница 50: ...50 Horno Con Vapor...