SkyLink DIAL-ALERT AD-105 Guide Скачать руководство пользователя страница 10

19

ADVANCED PROGRAMMING

Erase Programmed Panic Transmitters / Alarm Panels / Sensors

You may erase the programmed wireless devices, panic transmitter, alarm
panels and wireless sensors. You cannot erase a specific device, you must
erase all the devices and then program the ones that you would like to keep.

To erase all the wireless devices, follow the instructions below.

1. Enter the current password (factory default password is 0000), then

press [PROG], display will show [P] meaning you are now in
programming mode.

2. Enter [6] to erase programmed devices. Display shows [P6   ErASE].
3 Press [     ] to erase all programmed devices.
4. You have erased all the devices if you hear 2 beeps.

Dial Sequence

As mentioned, there is a Redial Count for each phone number, that means
when the dialed phone number is busy or cannot be connected, the Dial
Alert will dial the number again, or dial another phone number. You may
program it so it will finish dialing one phone number with all redial counts.

Example: There are 3 programmed phone numbers and the redial count for
these 3 phone numbers are all 2 times.

Factory default Dial Sequence: Dial each phone number once, then dial
each phone number the second time in the same sequence.
i.e. Phone #1, Phone #2, Phone #3, Phone #1, Phone #2, Phone #3.

Universal Dial Tone

You may setup the Dial Alert to dial only a proper dial tone if it is detected. If
no dial tone is detected, it will not dial. As there are many different dial
tones with different telephone systems or the tone is different in different
parts of the country, you may set it up so that the Dial Alert will dial no
matter what type of dial tone is detected. To enable a universal dial tone,
follow the instructions below.

1. Enter the current password (factory default password is 0000), then

press [PROG], display will show [P] meaning you are now in
programming mode.

2. Enter [*], then [1], display will show [P*1     2]

18

ADVANCED PROGRAMMING

Changing Password

Password is required for programming purposes. Factory default is 0000.
To change the setting, follow the instructions below.

1. Enter the current password (factory default password is 0000), then

press [PROG], display will show [P] meaning you are now in
programming mode.

2. Enter [2] to change password. Display now shows [nPIn], that means

New PIN.

3. Enter the new 4-digit password.
4. Display now shows [rPIn] meaning re-enter the new pin. Enter the new

4-digit password again.

5. If the new password is accepted, it will emit 2 beeps. If you don’t hear 2

beeps, that means the password is not accepted, retry again.

Calling Time

The Calling Time is how long the phone will ring before it is disconnected.
If the recipient does not pick up the phone after this time period, Dial Alert
will disconnect and redial. The factory default calling time is 45 seconds.
To change the setting follow the instructions below.

1. Enter the current password (factory default password is 0000), then press

[PROG], display will show [P] meaning you are now in programming mode.

2. Enter [7] to change the calling time. Display now shows [P7    2], the

most right digit represents the calling time setting. Refer to the table
below for the calling time setting.

1 - 30 seconds
2 - 45 seconds
3 - 60 seconds
4 - 75 seconds
5 - 90 seconds

3. Enter the desired value based on the table below. For example, enter [5]

to set the calling time to 90 seconds.

4. If the new setting is accepted, it will emit 2 beeps. If you don’t hear 2

beeps, that means the setting is not accepted, retry again.

Содержание DIAL-ALERT AD-105 Guide

Страница 1: ...86 1320 Email support skylinkhome com PAT D410633 6243000B1 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual please 1 visit our FAQ section at www skylinkhome com or 2 email us at support skylinkhome com or 3 call our toll free at 1 800 304 1187 from Monday to Friday 9 am to 5 pm EST Fax 800 286 1320 ...

Страница 2: ... Phone Number 13 Program a sensor under sensor operating mode 15 Testing 15 OPERATIONS 16 17 SC 001 Mode 16 Sensor Mode 16 Receiving a phone call 16 ADVANCEDPROGRAMMING 18 22 Changing Password 18 Program the Calling Time 18 Erase programmed Panic Transmitters Alarm Panels Sensors 19 Dial Sequence Setting 19 Universal Dial Tone 19 Pick up Pause Period 20 Entry Exit Delay For Sensor Mode 20 Arming D...

Страница 3: ...rks with SC 001 You can setup the AD 105 to communicate with a control panel SC 001 so when the SC 001 alarm is activated it will send a panic signal to the dialer and it will call you and other phone numbers up to 9 phone numbers and then playback a 40 second pre recorded message Sensor Mode Works with multiple sensors directly You can program sensors directly to the AD 105 so when any one of the...

Страница 4: ...rgency dialer 7 INSTALLATION The Dial Alert is installed using the screws provided We have also included double sided tape to use for temporary installation while you are positioning the dialer Once the dialer is positioned correctly install it permanently with screws We have also included wall anchors and a template to help position the screws correctly How to use the template 1 Cut the template ...

Страница 5: ...ews included to fix the front and back case together before hanging on to the wall When you open the case please remove theAC adapter and the phone line from the wall outlet 2 Thread the telephone line through the top hole in the back of the unit and plug it into the LINE jack If you want to have an answering machine on the same line as the dialer thread the phone line through the bottom hole in t...

Страница 6: ...rd voice messages Phone numbers you wish to dial during emergency up to 9 phone numbers Program the panic button or alarm panel to the dialer When you first power up the Dial Alert the display will show not rEAdy that means you don t have a voice recording and no phone number programmed You must perform the following programming steps in order for the Dial Alert to function during an emergency Not...

Страница 7: ...se and voice recording will stop when it reaches 0 You may also press at anytime to stop the voice recording 13 STANDARD PROGRAMMING 5 After recording the message you will hear the recorded message After the messageplayback it will quit fromprogrammingandreturntostandbymode 6 The display still shows not rEAdy because no phone number has been programmed MESSAGE PLAYBACK If you would like to listen ...

Страница 8: ...aler so theyknowexactly what happens when they receive your emergency message 7 The DialAlert is now in standby mode and the display shows rEAdy meaning you have recorded a voice message and have a least one phone number programmed Youmaysometimesneedtoinsertpauseperiodinaphonenum ber so you can pause the dialing process there are 2 types of pause periods 1 Normal Pause 2 Pick up Pause Normal Paus...

Страница 9: ... dial the programmed phone numbers and playback the voice message It is not necessary to put the AD 105 in arm mode Once the display shows rEAdy theAD 105 will respond if it receives a command to dial out Sensor Mode When the AD 105 operates in Sensor Mode it needs to be armed in order to respond to a sensor signal When the AD 105 is not armed it will not respond to any sensor activation except wh...

Страница 10: ...l tone is detected To enable a universal dial tone follow the instructions below 1 Enter the current password factory default password is 0000 then press PROG display will show P meaning you are now in programming mode 2 Enter then 1 display will show P 1 2 18 ADVANCED PROGRAMMING Changing Password Password is required for programming purposes Factory default is 0000 To change the setting follow t...

Страница 11: ... it will emit 2 beeps If you don t hear 2 beeps that means the setting is not accepted retry again Pick up Pause Period Pick up Pause allows you to have a pause period after the recipient picks up the call This is useful if you are sending a numeric message to a pager or sending a voice message to an answering machine You may define the pause period from 1 sec to 9 seconds To change the setting fo...

Страница 12: ...matically trigger the dialer to dial out all the preset telephone numbers and play the pre recorded message The other way to trigger the dialer by the existing alarm system is to use the Audio Sensor AS 101 in conjunction with the Dial Alert see Additional Accessories page 24 PANELORSENSOR N C LATCHING DRYCONTACT NORMALLYCLOSED OPENSALARM AD 105 Remove the jumper first Place the Audio Sensor besid...

Страница 13: ...itter HW 434 Wrist watch style Activates Security Control Panel and Emergency Dialer bypressingthepanicbuttonwhenunder duress Ideal for Seniors physically challenged Water resistant carry transmitter all the time Operates using lithium batteries included 24 Additional sensorsand transmitters as well asaddonaccessories are available to work with your Dial Alert ADDITIONAL ACCESSORIES Security Contr...

Страница 14: ...kaline battery included Vibration Sensor VS 101 Activates Security Control Panel or Emergency Dialer when vibration is detected Attach vibration sensor to valuables 3V lithium battery included 26 Garage Door Monitor Sensor GS 101 Place sensor on garage door Activates Security Control Panel or Emergency Dialer when the garage door is opened 3V lithium battery included TM ...

Отзывы: