27
Battery & charging instructions
Operation procedures
• Attention! Connect charger first to AC power before con
necting the battery to the charger. Plug into AC mains the
“power on” indicator will be on and the “Status” indicator
will be GREEN, then connecting the battery pack to charger.
• During charging, the “Status” indicator turns on RED.
When full, it turns on GREEN.
• To avoid the case of failed battery pack, when the charger
stays in precharge stage longer than 5 hours, it will stop
charging and the “Status” indicator will be pulsed with a
one second to indicate precharge error.
• During charging, user can Disconnect battery from charg
er any time as he/she wants.
Users also could start to charge the battery at any time.
The charger is able to determine the best cutin point
where the charging process is starting to.
• In case of problems, please check battery pack and repeat
above steps. If problem persist, please contact manufac
turer for assistance.
Check before Proceeding:
• Make sure battery pack is compatible with The charger
before connecting.
• The 3pin connector of the output cable is preset at the
factory. Do not swap their connections which may cause
serious hazards.
• The charger is designed for use only with lithium battery
packs and is not recommended for use with other battery
packs.
• The charger is a precise tool and should be kept away
from high power EMI radiating devices.
Mechanical Specification:
1. Dimension: 167*74*37 mm.
2. Weight: 410g approx.
3. Charger output: 3‐pin connector. (Pin 1‐ Positive ; Pin 2‐ Negative ; Pin 3‐ Negative )
4. AC socket: Standard 2‐p oblong.
5. AC cable: National wall plug type upon request.
Operation procedures:
1. Attention! Connect charger first to AC power *
before*
connecting the battery to the
charger
. Plug into AC mains the “power on” indicator will be on and the “Status”
indicator will be GREEN, then connecting the battery pack to charger.
2. During
charging, the “Status” indicator turns on RED. When full, it turns
on GREEN.
3.
To avoid the case of failed battery pack, when the charger stays in pre‐charge stage longer
than
5 hours, it will stop charging and the “Status”
indicator will be pulsed with a one
second
to indicate pre‐charge error.
LED 1
LED 2
Indicators
Condition
OFF
ON
Power On
(Power on by plugging in AC source and without battery)
Flashing in three times then ON
ON
OFF
Constant Current Mode
ON
OFF
Constant Voltage Mode
ON
ON
Battery Fully Charged
(Terminate Current
≤
300
±
100mA)
Slow Flash
OFF
Pre-Charged Mode
Red and Green LEDs
Flash synchronous
Pre-Charged Mode Fail
Red and Green LEDs
Quickly Flash alternately Over Voltage, Over Current, CC CV Mode Current Fail
21
3.The indicator signal chart
:
Содержание Tube+
Страница 1: ...05 2022 TUBE Gebruikershandleiding User Manual ...
Страница 50: ......
Страница 51: ......