SKYHYDRANT

 - USER GUIDE & DATA SHEET

OPERATING INSTRUCTIONS

SkyHydrant ultrafiltration units are ideal for supplying drinking water in remote 
locations from both surface and ground water supplies. SkyHydrants can be setup 
and operated by non-technical persons and require no power or replacement filters.

SKYHYDRANT SETTING UP

Select a secure undercover location for the SkyHydrant 
sheltered from sun and rain and install in an upright position. 
The site should be located in a well-drained position with access 
to a disposal area for the discharge of backwash water.

A maintenance person should undertake daily cleaning and 
servicing of the unit to ensure it’s continuous operation. Log 
sheets should also be completed to record water production 
and to schedule servicing of the unit.

SKYHYDRANT ASSEMBLY

Connect the Cleaning Handles

Unwind the head shaft a few turns anticlockwise to release 
pressure and remove the two temporary bolts used during 
shipping. Next, screw the two cleaning handles into the top 
of the SkyHydrant making sure they are firmly seated into 
position.

Attach Legs and/or Wall Brackets

Use fasteners provided to screw the legs onto the base of 
the unit and/or attach the wall mounting brackets to the back 
of the SkyHydrant which in turn can be secured to a wall or 
upright (see Fittings & Accessory Sheet for details).

Connect Plumbing Fittings

All outlets use 20mm (3/4”) BSP connectors and quick 
connect fittings. The taps numbers T1 “Dirty Water In” and T2 
“Backwash Out” can be folded down level for use. 

Setup Ancillary Connections

Connect hoses and fittings to allow the SkyHydrant to function 
i.e. Taps, pipes, tanks, pumps or other equipment (see How 
the Ultrafiltration Unit Works for details).

•  Connect “dirty water in” hose to T1 “Dirty Wash In”.
•  Connect “backwash out” hose to T2 “Backwash Out”.
•  Connect drinking water “clean water out” hose to T3 

“Clean Water Out”.

Содержание SkyHydrant-GEM

Страница 1: ......

Страница 2: ...TABLE OF CONTENTS Operating Instructions 01 How the SkyHydrant Works 04 How to Maintain Water Quality 06 Ultrafiltration Removal Criteria 08 Data Sheet 11 Operating Log 15...

Страница 3: ...GEM Nominal 6 000 litres per day SkyHydrant MAX Nominal 12 000 litres per day Height 143 cm Depth 18 cm Width 25 cm Mass dry 13 kg Mass wet 32 kg Height 82 cm Depth 18 cm Width 25 cm Mass dry 9 kg Mas...

Страница 4: ...nwind the head shaft a few turns anticlockwise to release pressure and remove the two temporary bolts used during shipping Next screw the two cleaning handles into the top of the SkyHydrant making sur...

Страница 5: ...ulations of contaminate Do this by moving the cleaning handles on top of the unit back forth at least daily and throughout the day This is necessary to maintain the correct flow of drinking water and...

Страница 6: ...al Clean follow Steps M1 to M8 After completion the unit can be returned back to producing drinking water again C1 C2 C3 C4 C5 C6 C7 C8 Solution Cleaning Using Citric Acid Undertake Monthly Citric aci...

Страница 7: ...ying water directly to houses through a distribution network Never pump or connect mains water pressure directly to the ultrafiltration unit without using a suitable water pressure regulating or contr...

Страница 8: ...oduced from the SkyHydrant can be stored in tanks and connected to taps or be piped to household supplies PERFORMANCE MONITORING At start up it is recommended the flow rate of the SkyHydrant be measur...

Страница 9: ...d approximately 1 teaspoon of chlorine powder to 5 litres of water and flush through pipes or wash drinking water containers It is also recommended to regularly flush a chlorinated solution through th...

Страница 10: ...event the growth of unwanted organisms and pathogens in the stored water To achieve this as a guide add about 3 4 teaspoon of chlorine powder at 65 available chlorine or 1 teaspoons of chlorine powder...

Страница 11: ...ved TSS is similar to turbidity 4 IRON AND MANGANESE if first oxidised or if colloidal can be removed by ultrafiltration 5 ARSENIC MANGANESE if first oxidised can be removed by ultra iltration The Wor...

Страница 12: ...alinity and salts are not removed by ultrafiltration include Salinity WHO safe drinking standard Max 250 mg L Chloride and Sodium WHO safe drinking standard Max 600 mg L Conductivity WHO safe drinking...

Страница 13: ...YHYDRANT USER GUIDE DATA SHEET T4 T1 T2 STEP ONE STEP TWO CONNECT CONNECT HANDLES CONNECT LEGS WALL BRACKETS OPTIONAL U LT R A F I LT R AT I O N U N I T ACCESSORY KIT U L T R A F I L T R A T I O N U N...

Страница 14: ...sources The treatment systems must provide pathogen free water economically and with minimal operator attendance SkyHydrant Water Filtration Units require no power or replacement filters and can be o...

Страница 15: ...The secret to the successful operation of the SkyHydrant is the effectiveness of its patented backwash system which uses a mechanical agitation process to clean membrane surfaces Backwashing is initia...

Страница 16: ...Feed Temperature Range Temperature Range for Tansportation and Storage Feed pH Range Maximum Housing Operating Pressure Membrane Module Details Materials of Construction Module Housing Assembly Valve...

Страница 17: ...C out of direct sunlight When SkyHydrants are being used for the first time it is recommended that a chlorinated backwash be carried out before the filtrate is used The filter sub module is resistant...

Страница 18: ...15 SKYHYDRANT USER GUIDE DATA SHEET TIME DATE DRINKING WATER PRODUCTION L MANUAL CLEANING UNDERTAKEN CHEMICAL CLEANING UNDERTAKEN AMOUNT CHLORINE USED OTHER INFORMATION OR NOTES OPERATING LOG...

Страница 19: ...16 SKYHYDRANT USER GUIDE DATA SHEET...

Страница 20: ......

Отзывы: