background image

11

SKYHYDRANT

 - USER GUIDE & DATA SHEET

DATA SHEET

Turbidity will also be removed and as turbidity rise the 
SkyHydrants will require more frequent cleaning cycles 
to remove accumulated contaminates. A pre-filter to 200 
microns is highly recommended to reduce module fouling in 
areas where high levels of solids are found.

The backwash cleaning cycle is easily undertaken requiring 
no tools or the need to access internal components of the 
SkyHydrant. Handles on top of the unit are simply moved 
back and forth for the mechanical agitation cleaning process 
which takes about one minute to complete before the back 
flush valve is opened to release contaminates.

BACKGROUND

Small communities require robust, reliable water treatment 
solutions often from difficult water sources. The treatment 
systems must provide pathogen free water economically and 
with minimal operator attendance.

SkyHydrant Water Filtration Units require no power or replacement filters and can be operated by non-
technical persons. SkyHydrants are lightweight and portable making them ideal for supplying drinking 
water in most remote locations from both surface and ground water supplies.

They can operate as single standalone units or be manifolded together to increase water flow to create 
large-scale water production plants.

SkyHydrants will significantly remove pathogens from feed water including bacteria, viruses, protozoa, 
cysts and parasites to a level as classified by the World Health Organisation (WHO) as suitable for drinking 
water.

TYPICAL APPLICATIONS 

• Decentralised water treatment systems
• Community small-scale systems
• Remote and rural
• Communities
• Point-of-entry filtration
• Emergency and temporary water supplies
• RO (reverse osmosis) pre-treatment

Содержание SkyHydrant-GEM

Страница 1: ......

Страница 2: ...TABLE OF CONTENTS Operating Instructions 01 How the SkyHydrant Works 04 How to Maintain Water Quality 06 Ultrafiltration Removal Criteria 08 Data Sheet 11 Operating Log 15...

Страница 3: ...GEM Nominal 6 000 litres per day SkyHydrant MAX Nominal 12 000 litres per day Height 143 cm Depth 18 cm Width 25 cm Mass dry 13 kg Mass wet 32 kg Height 82 cm Depth 18 cm Width 25 cm Mass dry 9 kg Mas...

Страница 4: ...nwind the head shaft a few turns anticlockwise to release pressure and remove the two temporary bolts used during shipping Next screw the two cleaning handles into the top of the SkyHydrant making sur...

Страница 5: ...ulations of contaminate Do this by moving the cleaning handles on top of the unit back forth at least daily and throughout the day This is necessary to maintain the correct flow of drinking water and...

Страница 6: ...al Clean follow Steps M1 to M8 After completion the unit can be returned back to producing drinking water again C1 C2 C3 C4 C5 C6 C7 C8 Solution Cleaning Using Citric Acid Undertake Monthly Citric aci...

Страница 7: ...ying water directly to houses through a distribution network Never pump or connect mains water pressure directly to the ultrafiltration unit without using a suitable water pressure regulating or contr...

Страница 8: ...oduced from the SkyHydrant can be stored in tanks and connected to taps or be piped to household supplies PERFORMANCE MONITORING At start up it is recommended the flow rate of the SkyHydrant be measur...

Страница 9: ...d approximately 1 teaspoon of chlorine powder to 5 litres of water and flush through pipes or wash drinking water containers It is also recommended to regularly flush a chlorinated solution through th...

Страница 10: ...event the growth of unwanted organisms and pathogens in the stored water To achieve this as a guide add about 3 4 teaspoon of chlorine powder at 65 available chlorine or 1 teaspoons of chlorine powder...

Страница 11: ...ved TSS is similar to turbidity 4 IRON AND MANGANESE if first oxidised or if colloidal can be removed by ultrafiltration 5 ARSENIC MANGANESE if first oxidised can be removed by ultra iltration The Wor...

Страница 12: ...alinity and salts are not removed by ultrafiltration include Salinity WHO safe drinking standard Max 250 mg L Chloride and Sodium WHO safe drinking standard Max 600 mg L Conductivity WHO safe drinking...

Страница 13: ...YHYDRANT USER GUIDE DATA SHEET T4 T1 T2 STEP ONE STEP TWO CONNECT CONNECT HANDLES CONNECT LEGS WALL BRACKETS OPTIONAL U LT R A F I LT R AT I O N U N I T ACCESSORY KIT U L T R A F I L T R A T I O N U N...

Страница 14: ...sources The treatment systems must provide pathogen free water economically and with minimal operator attendance SkyHydrant Water Filtration Units require no power or replacement filters and can be o...

Страница 15: ...The secret to the successful operation of the SkyHydrant is the effectiveness of its patented backwash system which uses a mechanical agitation process to clean membrane surfaces Backwashing is initia...

Страница 16: ...Feed Temperature Range Temperature Range for Tansportation and Storage Feed pH Range Maximum Housing Operating Pressure Membrane Module Details Materials of Construction Module Housing Assembly Valve...

Страница 17: ...C out of direct sunlight When SkyHydrants are being used for the first time it is recommended that a chlorinated backwash be carried out before the filtrate is used The filter sub module is resistant...

Страница 18: ...15 SKYHYDRANT USER GUIDE DATA SHEET TIME DATE DRINKING WATER PRODUCTION L MANUAL CLEANING UNDERTAKEN CHEMICAL CLEANING UNDERTAKEN AMOUNT CHLORINE USED OTHER INFORMATION OR NOTES OPERATING LOG...

Страница 19: ...16 SKYHYDRANT USER GUIDE DATA SHEET...

Страница 20: ......

Отзывы: