Page 50
December 2007
Rough Terrain Scissors
TM
Start Operation
Section 3 - Operation
3.8-10 Generator (If Equipped)
To start generator:
1.
On platform control console, select lift/drive switch
to “
” lift position.
2.
On outrigger/generator control console, select
generator switch to “
” energized position. The
engine will automatically switch to low throttle and
the generator will start.
To restore normal operation:
3.
Flip generator switch to “ ” off position. The
generator will turn off.
NOTE
Activating any lift or outrigger functions,
changing key switch settings, activating
emergency stop or an engine stall will turn
off the generator. The platform may be
lowered during generator operation.
3.8-11 Electrical Inverter (If Equipped)
The inverter is operational with alternating current
available at all times when the machine is on. The
emergency stop button will turn the inverter off.
To check status of inverter:
1.
Inverter state is indicated by the LEDs on the face
of the inverter. A glowing green LED indicates
normal operation. If a fault occurs, the status
LEDs will indicate the area responsible. Refer to
3.8-12 Shutdown Procedure
1.
Completely lower the platform.
2.
On platform control console, push in “
”
emergency stop button.
WARNING
Ensure that you maintain three points of
contact when using the ladder to mount/
dismount platform.
3.
Use the ladder to dismount from platform.
4.
On base control console, push in “
” emergency
stop button.
5.
Turn platform/engine/base key switch to “
”
engine position and remove key.
6.
Turn main power disconnect switch to “ ” off
position.
Содержание SJ6826 RT
Страница 1: ...ROUGH TERRAIN SCISSORS MODELS SJ6826 RT SJ6832 RT 159172AA A December 2013 OPERATING MANUAL AS...
Страница 55: ...Rough Terrain Scissors December 2007 Page 55 Notes...
Страница 90: ...Page 90 December 2007 Rough Terrain Scissors TM Notes...
Страница 91: ......
Страница 92: ...www skyjack com P litelig lift l sninger av folk som bryr seg...