155
SJ3220, SJ3226, SJ4720, SJ4726, SJ4732
223198ABA
Skycoded Module
Section 5 – Procedures
Menu
Selection
Sub-Menu
Description
ACCESS LEVEL
CODE xxxx
ACCESS LEVEL” 3 prevents adjustments and calibrations (default)
ACCESS LEVEL” 2 allows calibrations (requires correct code)
“ACCESS LEVEL” 1 allows adjustments and calibrations (factory level)
“PUMPMODE” allows troubleshooting without Hydraulic pump function
When the Display Module is connected and powered on, the initial “ACCESS LEVEL” level 3 by default and
adjustments cannot be altered and calibrations cannot be carried out.
Before Calibrations can be done, the “ACCESS LEVEL” must be changed to level 2 using the correct access code.
ACCESS LEVEL 2 allows calibrations and allows some adjustments to be changed.
Adjustments should only be attempted by qualified individuals.
SYSTEM OVERRIDE*
Press ENTER to ENTER into OVERRIDE mode.
RUN SYSTEM TEST
TEST VALVES
Press ENTER to run rolling test of all valves coils on at a time. Coils will be energized in a rolling pattern. Any short
circuits or incorrect feedback will be displayed. Press ESC to skip to the next test.
TEST LAMPS
Press ENTER to run rolling test of all lamps, Press ESC to skip to the next test
TEST INPUTS
Press ENTER to run a rolling test of all inputs. This requires the tester to manually operate the switches when
requested. Press ESC to skip to the next test.
ADJUSTMENTS (Access level 1 required unless highlighted in grey)
D
R
IV
E
FWD MIN
Determines the slowest drive speed in the forward direction (when the joystick is at 0% demand)
FWD MAX
Determines the fastest drive speed in the forward direction (when the joystick is at 100% demand)
REV MIN
Determines the slowest drive speed in the reverse direction (when the joystick is at 0% demand)
REV MAX
Determines the fastest drive speed in the reverse direction (when the joystick is at 100% demand)
ACCEL
Determines the rate of increase of drive speed when higher speeds are demanded
DECEL
Determines the rate of decrease of drive speed when lower speeds (or stop) are demanded
MAX HEIGHT
Determines the height above which drive is prevented.
HOLD-OFF
Sets a delay time to keep drive valve turned on after ramping to a stop (if needed to avoid locking wheels at
stop)
BRAKE DELAY
Sets a delay time for when the brakes are activated
TORQUE
SCALE
Sets the torque scale
D
R
IV
E
/E
L
E
V
A
T
E
D
FWD MIN
Determines the slowest drive speed in the forward direction (when the joystick is at 0% demand) when elevated
FWD MAX
Determines the fastest drive speed in the forward direction (when the joystick is at 100% demand) when
elevated
REV MIN
Determines the slowest drive speed in the reverse direction (when the joystick is at 0% demand) when elevated
REV MAX
Determines the fastest drive speed in the reverse direction (when the joystick is at 100% demand) when
elevated
ACCEL
Determines the rate of increase of drive speed when higher speeds are demanded when elevated
DECEL
Determines the rate of decrease of drive speed when lower speeds (or stop) are demanded when elevated
HOLD-OFF
Sets a delay time to keep drive valve turned on after ramping to a stop when elevated
L
IF
T
UP MIN
Determines the slowest lifting speed (when the joystick is at 0% demand)
UP MAX
Determines the fastest lifting speed (when the joystick is at 100% demand)
Skycoded Control Module Menu Table (Continued)
Items highlighted in grey requires access level 2.
Содержание SJ 3220
Страница 4: ...4 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Страница 44: ...44 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Страница 45: ...45 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Section 3 System Component Identification and Schematics...
Страница 74: ...74 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Страница 93: ...93 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Страница 175: ...175 SJ3220 SJ3226 SJ4720 SJ4726 SJ4732 223198ABA Notes...
Страница 176: ......
Страница 177: ...www skyjack com...