3. Overload Indicato

r

The Overload Indicator (red) illuminates at a pre-set
value of 100% of Maximum Rated Capacity and pro-
vides a visual indication of Maximum Allowed Load.  It
will also illuminate whenever a wire rope limit is exceed-
ed.  Function limiters will occur simultaneously for an
Overload, Wire Rope Limit, or a Two Block condition
but function limiters will not occur when exceeding an
operator settable alarm.  An audible alarm will sound
and a message will appear in the warning message
area for all 4 conditions.

4. Maximum Rated Capacity Display

The Maximum Rated Capacity is a digital display of the
maximum permitted capacity.  It is derived from a copy
of the crane’s capacity chart which is stored in the com-
puter memory and is the reference capacity for any lift-
ing operation.  It is dependent on the configuration cur-
rently selected, which is shown in the crane setup
screen, and which determines the section of the ca-
pacity chart to be used as the rated capacity reference.

5. Actual Load Display

The Actual Load Display is a digital display which
shows total load suspended below the boom or fly
head.  It includes the load, any slings, pins, or tackle
used to secure the load and the hook block or ball.

6. Parts-of-Line Display

Parts-of-Line displays the parts of line currently se-
lected for the winch in use.

7. Configuration Selection Buttons

These buttons are used during the crane configuration
selection routine.  Refer to Configuration Selection"
found later in this Section of the Operator’s Manual.

8. Cancel Alarm Button

This button is used to silence the audible alarm when
the alarm has occurred as a result of either an Over-
load, Wire Rope Limit, a Two Block, or an Operator Set-
table alarm.  It is also used to reset the function limit
relay when it is necessary to by-pass function limit
which has occurred as a result of either an Overload,
Wire Rope Limit, or a Two Block alarm.

9. Operator Alarms Button

This button is used to start the operator settable alarms
routines.  Refer to Operator Settable Alarms" found
later in this section of the Operator’s Manual.

10. Crane Setup Button

This button is used to start the configuration selection
routine.  Refer to Configuration Selection" found later
in this Section of the Operator’s Manual.

11. Display/Select Button

This button is used to access the Calibration And Diag-
nostic Screen.  Refer to System Fault Codes" and
Calibration" found later in this Section of the Opera-
tor’s Manual.

12. Warning Message Area

The Warning Message Area displays text messages of
various alarms which may occur during normal opera-
tion of the system.  When an alarm occurs, the rectan-
gular area fills in red.

13

.

Boom Length Display

The Boom Length Display gives a continuous indica-
tion of the boom length in feet (

m

).  It is the distance

from the centerline of the boom foot pin to the center
line of the boom head machinery.

14. Brightness Buttons

These buttons are used to adjust the display bright-
ness.

15. Load Radius Display

The Load Radius Display gives a continuous indication
of the radius of the load in feet (

m

).  It is the horizontal

distance from the centerline of rotation to the centerline
of the hook.

16. Boom Angle Display

The Boom Angle Display gives a continuous indication
of the angle of the main boom relative to horizontal.

17. Erected Attachment Display

The Erected Attachment Display gives a continuous
display of the erected attachment with the top number
indicating the actual fly length and the bottom number
indicating the offset angle if applicable.

MicroGuard 534

Operator's Manual

SkyAzúl, Equipment Solutions

www.skyazul.com 
            3

301-371-6126

Содержание MicroGuard 534

Страница 1: ...MicroGuard 534 Operator s Manual...

Страница 2: ......

Страница 3: ...y information which is protected by copyright and all rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of...

Страница 4: ......

Страница 5: ...TEM SELF TEST 4 SYSTEM BYPASS 4 CONFIGURATION SELECTION 5 NORMAL WORKING SCREEN EXAMPLES 9 SELECTION OF RIGGING TRAVEL MODE 11 CANCEL AUDIBLE ALARM AND RESET FUNCTION LIMITERS 11 OPERATOR SETTABLE ALA...

Страница 6: ......

Страница 7: ...arm Button 9 Operator Alarms Button 10 Crane Setup Button 11 Display Select Button 12 Warning Message Area 13 Boom Length Display 14 Brightness Buttons 15 Load Radius Display 16 Boom Angle Display 17...

Страница 8: ...ure of the system is the provision of operator settable alarms These alarms when proper ly set provide a method of obstacle avoidance This is achieved by means of maximum boom angle maxi mum load radi...

Страница 9: ...le alarm It is also used to reset the function limit relay when it is necessary to by pass function limit which has occurred as a result of either an Overload Wire Rope Limit or a Two Block alarm 9 Op...

Страница 10: ...wn 1 Steps shall be taken to schedule repairs and recal ibration immediately The operational aids shall be put back into service as soon as replacement parts if required are available and the repairs...

Страница 11: ...may not appear or may not appear as illustrated The system cannot be programmed for configurations not allowed by the capacity charts listed in the Crane Rating Manual Figure 1 71 Carrier Selection 1...

Страница 12: ...ty at working radius Boom mode options will only be displayed when the boom is fully re tracted Figure 1 74 Auxiliary Head Selection 4 The boom mode selection screen will change and graphically displa...

Страница 13: ...se lect the rear winch not in use Figure 1 78 Front Winch Lifting Point Selection 8 If the crane is equipped with a front winch the rear winch lifting point screen will change and graphical ly display...

Страница 14: ...n selection button to select the actual parts of line for the front winch Note From the normal working screen after crane setup has been established only two selection buttons are active the winch sel...

Страница 15: ...e reeved over the fly base 7 with one part of line 8 and an operator settable alarm enabled 9 In this example the crane is setup on intermediate extended out riggers 1 boom mode B 2 12 000 lb counterw...

Страница 16: ...main boom 5 with three parts of line 6 and the 61 fly stowed 7 In this example the crane is setup on fully retracted outriggers 1 boom mode B 2 12 000 lb of counterweight 3 winch rope reeved over the...

Страница 17: ...would cause the au dible alarm to be re started WARNING Once the function limiters have been by passed the crane is no longer protected against the condition that initially caused the function limite...

Страница 18: ...3 Position the boom in the desired position depend ing upon the alarm to be set The numerical value displayed will be the current position of the boom 4 Press the corresponding selection button to se...

Страница 19: ...ceeds the alarm points and Swing Alarm will appear in warning message area Note Both the left and right swing alarms must be set for the system to determine the operator set working area Note An alarm...

Страница 20: ...e the right alarm setting 5 Position the boom attachment load rigging etc to the left alarm point and press the corresponding button to enter the left alarm point The dis played value will be the left...

Страница 21: ...Figure 1 88 Operator Defined Area Alarm IlIIIIIIlnary Vertlclll Plane RlahtAiann Polnt Working Area MicroGuard 534 Operator s Manual SkyAz l Equipment Solutions www skyazul com 15 301 371 6126...

Страница 22: ...at the top of the screen This informa tion can then be used to assist the service technician in determining the fault Contact your distributor for as sistance with the fault codes Calibration If the s...

Страница 23: ......

Страница 24: ...SkyAz l Equipment Solutions www skyazul com 301 371 6126 SkyAz l Inc 16 Walnut Street Middletown MD 21769 Phone 301 371 6126 Fax 301 371 0029 info skyazul com www skyazul com...

Отзывы: