LL Lenght (loop-loop)
Wire length
1) Before checking the wire length, pre-tension the line by the load of 22 kilograms for about
3 seconds per each line.
2) Always measure the wire length only when the line is tensioned by 5 kilograms.
3) If you need to cut the new line, the line has to be stabilized by the tension of 22 kilograms
and only then could be cut under the tension of 5 kilograms.
LINE SPECIFICATIONS |
KEA 2 XS
NAME
QUANTITY MATERIAL
LL LENGTH WIRE LENGTH
Certification glider
A1
2
Top line 16175
177,3
635,7
635,2
A2
2
Top line 16175
170,1
628,5
627,9
A3
2
Top line 16175
173,1
631,5
630,9
AU1
2
Vectraline 12470
459,2
reinforced
A4
2
Top line 16175
175,6
628,8
628,1
A5
2
Top line 16175
169,0
622,2
621,7
A6
2
Top line 16175
172,5
625,7
625,1
AU2
2
Vectraline 12470
454,0
reinforced
A7
2
Top line 16175
128,8
624,8
624,0
A8
2
Top line 16175
120,8
616,8
616,2
A9
2
Top line 16175
116,3
612,3
611,5
A10
2
Top line 16175
113,8
609,8
608,8
AO
4
Top line 16175
118,8
reinforced both sides
AU3
2
Vectraline 16330
378,3
B1
2
Top line 16175
177,2
628,6
628,0
B2
2
Top line 16175
170,1
621,5
620,7
B3
2
Top line 16175
173,1
624,5
623,6
BU1
2
Vectraline 12470
452,2
reinforced
B4
2
Top line 16175
175,2
622,0
621,5
B5
2
Top line 16175
169,0
615,8
615,1
B6
2
Top line 16175
172,9
619,7
619,1
BU2
2
Vectraline 12470
447,6
reinforced
B7
2
Top line 16175
126,3
619,9
619,1
B8
2
Top line 16175
120,0
613,6
612,6
B9
2
Top line 16175
117,2
610,8
609,8
B10
2
Top line 16175
115,6
609,2
608,2
BO
4
Top line 16175
118,8
reinforced both sides
BU3
2
Vectraline 16330
375,9
NAME
QUANTITY MATERIAL
LL LENGTH WIRE LENGTH
Certification glider
C1
2
Top line 16175
167,8
630,7
630,2
C2
2
Top line 16175
160,3
623,2
622,5
C3
2
Top line 16175
163,7
626,6
626,0
CU1
2
Vectraline 16330
463,5
reinforced
C4
2
Top line 16175
165,8
624,2
623,3
C5
2
Top line 16175
159,3
617,7
616,9
C6
2
Top line 16175
163,7
622,1
621,2
CU2
2
Vectraline 16330
459,0
reinforced
C7
2
Top line 16175
120,5
626,6
626,2
D7
2
Top line 16175
122,3
628,4
628,0
C8
2
Top line 16175
113,5
619,6
619,1
C9
2
Top line 16175
110,2
616,3
615,9
D8
2
Top line 16175
112,5
618,6
618,2
C10
2
Top line 16175
108,3
614,4
613,9
CO
4
Top line 16175
112,1
reinforced both sides
CU3
2
Vectraline 16330
395,1
D1
2
Top line 16175
158,3
641,0
640,4
D2
2
Top line 16175
150,6
633,3
632,3
D3
2
Top line 16175
154,9
637,6
636,6
DU1
2
Vectraline 16330
483,3
reinforced
D4
2
Top line 16175
156,7
635,4
634,9
D5
2
Top line 16175
149,7
628,4
628,0
D6
2
Top line 16175
154,5
633,2
632,7
DU2
2
Vectraline 16330
479,3
reinforced
NAME
QUANTITY MATERIAL
LL LENGTH WIRE LENGTH
Certification glider
A11
2
Top line 16175
107,6
590,8
590,9
A12
2
Top line 16175
97,3
580,5
580,4
B11
2
Top line 16175
105,4
588,6
588,5
C11
2
Top line 16175
110,6
593,8
594,0
SA
2
Top line 16175
87,7
570,9
571,0
SB
2
Top line 16175
87,3
570,5
570,5
SC
2
Top line 16175
90,4
573,6
573,6
SO
4
Top line 16175
142,1
reinforced both sides
SU
2
Vectraline 16330
342,2
F1
2
Top line 16175
172,4
710,9
712,7
F2
2
Top line 16175
151,8
690,3
692,1
F3
2
Top line 16175
137,7
676,2
678,2
F4
2
Top line 16175
130,6
669,1
671,0
F5
2
Top line 16175
122,1
660,6
662,3
F6
2
Top line 16175
111,1
649,6
651,3
F7
2
Top line 16175
107,3
645,8
647,7
F8
2
Top line 16175
109,6
648,1
649,8
F9
2
Top line 16175
103,6
642,1
643,7
F10
2
Top line 16175
98,9
637,4
638,7
F11
2
Top line 16175
93,8
632,3
633,7
F12
2
Top line 16175
89,1
627,6
629,1
FOO
12
Top line 16175
108,7
FOU
6
7850-080-040
216,8
FU
2
7850-200-040
216,6
Measurements done according to the EN standard 926-2 |2013 (measured under a tension of 50N)