background image

TAB TEXT HERE

TAB TEXT HERE

TAB TEXT HERE

TAB TEXT HERE

TAB TEXT HERE

E N V I R O L I N K   M A N U A L

 REV 04/24/06

ENVIROLINK MANUAL (CONTINUED)

(continued)

To select an option:

From 

Idle Mode

, Press 

MENU

 until the display reads 

CNFG

 (Configuration) and press 

ENTER

.

Press 

MENU

 until the display reads 

OUT4

 (Output 4).  Press 

ENTER

.

Press 

MENU

 until you reach the option you want and press 

ENTER

.  (Do not select 

PCT

)

Programming the Skutt KilnMaster 600 for use with the EnviroLink

OP A (Option A)

When Option A is selected Output 4 will turn on when a 

ConeFire Mode

 program is started.  When the 

program has run and the kiln has cooled to 150 °F output 4 will turn off.  
When a 

Ramp/Hold

 program is entered it will ask whether you want the fan (or other accessory) on  for 

each segment you program.  After you enter the hold time for each segment the display will show 

FAN

 

along with the number of the segment you are programming.  Alternately it will flash the current setting, 

either 

OFF

 or 

ON

.  To change the setting toggle it with the 1 key and press 

ENTER

 to select that setting.

OP b (Option B)

During a 

ConeFire

 program Output 4 will turn on when 

START

 is pressed.  It will then turn off at 1450 °F.  

It will turn back on when the kiln is cooling and the temperature drops below 1000 °F.  It will then turn 

off when the kiln cools to 150 °F.
 When a 

Ramp/Hold

 program is entered it will ask whether you want the fan (or other accessory) on  for 

each segment you program.  After you enter the hold time for each segment the display will show 

FAN

 

along with the number of the segment you are programming.  Alternately it will flash the current setting, 

either 

OFF

 or 

ON

.  To change the setting toggle it with the 

1

 key and press 

ENTER

 to select that setting.

OP C (Option C)

When Option C is selected Output 4 does not come on during any portion of a 

ConeFire Mode

 program.

When a 

Ramp/Hold

 program is entered it will ask whether you want the fan (or other accessory) on  for 

each segment you program.  After you enter the hold time for each segment the display will show 

FAN

 

along with the number of the segment you are programming.  Alternately it will flash the current setting, 

either 

OFF

 or 

ON

.  To change the setting toggle it with the 1 key and press 

ENTER

 to select that setting.

ALR4 (Alarm 4)

This is the factory default setting.  If Output 4 is not being utilized this is the setting that should be 

selected.  This feature can also control an external alarm or autodialer to initiate if an Error Code is 

generated or if the internal temperature of the kiln reaches the temperature programmed for the 

ALARM

 

setting of the program.  To deactivate the alarm press 

ENTER

.

To select an option:

From

 IDLE Mode

, Press 

MENU

. You will see

 CHG °

Press:

 

8

 then 

2

 for Option A

 

8

 then 

3

 for Option B

 

8

 then 

4

 for Option C

 

8

 then 

5

 for Alarm 4

1.
2.
3.

1.
2.

Содержание EnviroVent

Страница 1: ...he EnviroLink which provides power to the device A red indicator light signals that there is power to the EnviroLink and a green indicator light signals that the EnviroVent is in the ON position The EnviroLink will only work with 600 and 700 series Skutt GlassMaster and KilnMaster Controllers manufactured after January 1st of 2001 The EnviroLink is rated to cycle components up to 12 amps Consult t...

Страница 2: ... the controller s connector that is closest to the round black speaker at the top of the board This is marked Output 4 on the KM 600 and GM 600 boards not marked on some GM 700 boards Screw the controller back in place Plug the EnviroLink into a 120V outlet and your vent into the EnviroLink Plug in the kiln The installation is complete Be sure the in line toggle switch on the vent is in the on pos...

Страница 3: ...nt setting either OFF or ON To change the setting toggle it with the 1 key and press ENTER to select that setting OP b Option B When Option B is selected Output 4 will turn on only during segment 6 of a GlassFire Mode program This program is designed to limit a fan from coming on when fusing extremely sensitive large pieces of glass It will come on between the process temperature and the annealing...

Страница 4: ...iln cools to 150 F When a Ramp Hold program is entered it will ask whether you want the fan or other accessory on for each segment you program After you enter the hold time for each segment the display will show FAN along with the number of the segment you are programming Alternately it will flash the current setting either OFF or ON To change the setting toggle it with the 1 key and press ENTER to...

Страница 5: ...g either OFF or ON To change the setting toggle it with the 1 key and press ENTER to select that setting OP C Option C When Option C is selected Output 4 does not come on during any portion of a ConeFire Mode program When a Ramp Hold program is entered it will ask whether you want the fan or other accessory on for each segment you program After you enter the hold time for each segment the display ...

Страница 6: ...RE TAB TEXT HERE E N V I R O L I N K M A N U A L REV 04 24 06 ENVIROLINK MANUAL CONTINUED To EnviroLink Marked on 700 Board Marked Output 4 on 600 Board Marked Center Tap on 600 and 700 Board 600 and 700 Circuit Board Does not exist on 600 Board Red Black ...

Отзывы: