Skutt EnviroVent Скачать руководство пользователя страница 2

TAB TEXT HERE

TAB TEXT HERE

TAB TEXT HERE

TAB TEXT HERE

TAB TEXT HERE

E N V I R O L I N K   M A N U A L

 REV 04/24/06

ENVIROLINK MANUAL (CONTINUED)

(continued)

INSTALLING THE ENVIROLINK

U

NPLUG

 

THE

 

KILN

.

Remove the four screws that hold the control panel in place on the face of the Control box.
Drill a 7/16” hole in the side of the kiln control box on either side up near the top.  Be careful not to hit 

any components or wires.  You should be able to locate a good spot by looking through the mounting 

hole for the controller.  If you cannot see whether or not you have a clear path for drilling, we 

recommend that you remove the control box from the kiln and open the heat baffle for a clearer view.
Pass the 

EnviroLink

 cable through the hole.

Make sure there is sufficient wire length to plug the wires into the controller.   Place the strain relief 

(black plastic plug) around the cable on the outside of the control box and close the connector.  Push 

the strain relief and cable into the hole. 
Unplug the wires on the Center Tap output of the controller.  It is labeled in white letters on the right 

side of the board.
The black wire from the 

EnviroLink

 cable is a piggyback connector.  Plug this onto the controller’s 

Center Tap.
Plug the wires that you removed onto the piggyback connector.
Plug the red wire from the 

EnviroLink

 cable onto the controller’s connector that is closest to the round 

black speaker at the top of the board.  This is marked Output 4 on the KM 600 and GM 600 boards (not 

marked on some GM 700 boards).
Screw the controller back in place.
Plug the 

EnviroLink

 into a 120V outlet and your vent into the 

EnviroLink

.

Plug in the kiln.  The installation is complete.  (Be sure the in-line toggle switch on the vent is in the on 

position.)

PROGRAMMING THE ENVIROLINK

Once the 

EnviroLink

 has been installed, the controller must be configured to use it.  There are four optional 

settings that control how the 

EnviroLink

 cycles the power to the vent.   Programming instructions vary 

slightly depending on the controller and the version of the controller.

GlassMaster

 600 Board (Red LED Display) 1/02 - 1/8/06

KilnMaster

 600 Board (Red LED Display) 1/01 - 3/20/06

GlassMaster

 700 Board (Green LED Display) 1/9/06 to present

KilnMaster

 700 Board (Green LED Display) 3/21/06 to present

Programming the Skutt GlassMaster 600 for use with the EnviroLink

OP A (Option A), OP b (Option B), OP C (Option C)

In the 600 Board version of the GlassMaster Controller Option A, B, and C are the same.  When these 

options are selected the 

EnviroLink

 will turn on when the kiln is started and turn off when it is complete if 

you are using 

GlassFire Mode

.  If you are using 

Ramp/Hold Mode

 to program your kiln it will ask you at the 

end of each segment while programming whether you want to have the 

FAN ON

 or 

OFF

.  Use the 

1

 key to 

toggle between 

ON

 and 

OFF

 and then press 

ENTER

.

1.
2.

3.
4.

5.

6.

7.
8.

9.
10.
11.

Содержание EnviroVent

Страница 1: ...he EnviroLink which provides power to the device A red indicator light signals that there is power to the EnviroLink and a green indicator light signals that the EnviroVent is in the ON position The EnviroLink will only work with 600 and 700 series Skutt GlassMaster and KilnMaster Controllers manufactured after January 1st of 2001 The EnviroLink is rated to cycle components up to 12 amps Consult t...

Страница 2: ... the controller s connector that is closest to the round black speaker at the top of the board This is marked Output 4 on the KM 600 and GM 600 boards not marked on some GM 700 boards Screw the controller back in place Plug the EnviroLink into a 120V outlet and your vent into the EnviroLink Plug in the kiln The installation is complete Be sure the in line toggle switch on the vent is in the on pos...

Страница 3: ...nt setting either OFF or ON To change the setting toggle it with the 1 key and press ENTER to select that setting OP b Option B When Option B is selected Output 4 will turn on only during segment 6 of a GlassFire Mode program This program is designed to limit a fan from coming on when fusing extremely sensitive large pieces of glass It will come on between the process temperature and the annealing...

Страница 4: ...iln cools to 150 F When a Ramp Hold program is entered it will ask whether you want the fan or other accessory on for each segment you program After you enter the hold time for each segment the display will show FAN along with the number of the segment you are programming Alternately it will flash the current setting either OFF or ON To change the setting toggle it with the 1 key and press ENTER to...

Страница 5: ...g either OFF or ON To change the setting toggle it with the 1 key and press ENTER to select that setting OP C Option C When Option C is selected Output 4 does not come on during any portion of a ConeFire Mode program When a Ramp Hold program is entered it will ask whether you want the fan or other accessory on for each segment you program After you enter the hold time for each segment the display ...

Страница 6: ...RE TAB TEXT HERE E N V I R O L I N K M A N U A L REV 04 24 06 ENVIROLINK MANUAL CONTINUED To EnviroLink Marked on 700 Board Marked Output 4 on 600 Board Marked Center Tap on 600 and 700 Board 600 and 700 Circuit Board Does not exist on 600 Board Red Black ...

Отзывы: