![Skutt EnviroVent Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/skutt/envirovent/envirovent_manual_1289551002.webp)
TAB TEXT HERE
TAB TEXT HERE
TAB TEXT HERE
TAB TEXT HERE
TAB TEXT HERE
E N V I R O L I N K M A N U A L
REV 04/24/06
ENVIROLINK MANUAL (CONTINUED)
(continued)
INSTALLING THE ENVIROLINK
U
NPLUG
THE
KILN
.
Remove the four screws that hold the control panel in place on the face of the Control box.
Drill a 7/16” hole in the side of the kiln control box on either side up near the top. Be careful not to hit
any components or wires. You should be able to locate a good spot by looking through the mounting
hole for the controller. If you cannot see whether or not you have a clear path for drilling, we
recommend that you remove the control box from the kiln and open the heat baffle for a clearer view.
Pass the
EnviroLink
cable through the hole.
Make sure there is sufficient wire length to plug the wires into the controller. Place the strain relief
(black plastic plug) around the cable on the outside of the control box and close the connector. Push
the strain relief and cable into the hole.
Unplug the wires on the Center Tap output of the controller. It is labeled in white letters on the right
side of the board.
The black wire from the
EnviroLink
cable is a piggyback connector. Plug this onto the controller’s
Center Tap.
Plug the wires that you removed onto the piggyback connector.
Plug the red wire from the
EnviroLink
cable onto the controller’s connector that is closest to the round
black speaker at the top of the board. This is marked Output 4 on the KM 600 and GM 600 boards (not
marked on some GM 700 boards).
Screw the controller back in place.
Plug the
EnviroLink
into a 120V outlet and your vent into the
EnviroLink
.
Plug in the kiln. The installation is complete. (Be sure the in-line toggle switch on the vent is in the on
position.)
PROGRAMMING THE ENVIROLINK
Once the
EnviroLink
has been installed, the controller must be configured to use it. There are four optional
settings that control how the
EnviroLink
cycles the power to the vent. Programming instructions vary
slightly depending on the controller and the version of the controller.
GlassMaster
600 Board (Red LED Display) 1/02 - 1/8/06
KilnMaster
600 Board (Red LED Display) 1/01 - 3/20/06
GlassMaster
700 Board (Green LED Display) 1/9/06 to present
KilnMaster
700 Board (Green LED Display) 3/21/06 to present
Programming the Skutt GlassMaster 600 for use with the EnviroLink
OP A (Option A), OP b (Option B), OP C (Option C)
In the 600 Board version of the GlassMaster Controller Option A, B, and C are the same. When these
options are selected the
EnviroLink
will turn on when the kiln is started and turn off when it is complete if
you are using
GlassFire Mode
. If you are using
Ramp/Hold Mode
to program your kiln it will ask you at the
end of each segment while programming whether you want to have the
FAN ON
or
OFF
. Use the
1
key to
toggle between
ON
and
OFF
and then press
ENTER
.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
•
•
•
•