background image

6441 SE Johnson Creek Blvd., Portland, OR 97206

           

Phone (503) 774-6000       Fax (503) 774-7833

www.skutt.com

TAB TEXT HERE

TAB TEXT HERE

TAB TEXT HERE

TAB TEXT HERE

E N V I R O L I N K   M A N U A L

 REV 04/24/06

(continued)

 

EnviroLink Manual

 

 

 

 

INTRODUCTION

The 

EnviroLink

 was developed by engineers at Skutt to 

provide kiln owners with the ability to automatically control 

the Skutt 

EnviroVent 

and 

EnviroVent 2

.   The device utilizes 

a programmable power output (OUTPUT 4) on Skutt 

KilnMaster 

and 

GlassMaster

 Controllers to turn on/off the 

EnviroVent

 and 

EnviroVent

 2.  The kiln may be programmed 

to control the vent during any segment of a 

Ramp/Hold

 

Program or during preset times of a 

ConeFire

 or 

Glass Fire 

Mode

 program.  

The 

EnviroLink

 may also be used to control competitor’s kiln 

vents and other devices such as remote alarms and automatic 

dialers.  The vent, or other device, plugs into the 

EnviroLink

 

and a control wire is run from the 

EnviroLink

 to a designated 

output (Output 4) on the controller.   The 

EnviroLink

 is then 

plugged into a standard 120V outlet.   When the controller 

signals the device to turn ON, a relay is switched within 

the 

EnviroLink

 which provides power to the device.   A red 

indicator light signals that there is power to the 

EnviroLin

and a green indicator light signals that the 

EnviroVent

 is in 

the ON position
The 

EnviroLink

 will only work with 600 and 700 series 

Skutt 

GlassMaster

 and 

KilnMaster

 Controllers manufactured 

after January 1st of 2001. The 

EnviroLink

 is rated to cycle 

components up to 12 amps.  Consult the manufacturer 

prior to installing the 

EnviroLink

 on devices other than the 

EnviroVent

 or 

EnviroVent 2

.

WHO CAN BENEFIT FROM AN ENVIROLINK?

Teachers 

- Even though most vents do not draw a lot of energy, most teachers do not feel comfortable 

letting the fan motor run all weekend or even overnight.  The EnviroLink will shut the kiln off when 

the program is complete or when the kiln reaches a specific temperature.  Since it works with ConeFire 

Mode, it is very easy to program.

Potters

 - Crystal Glazes and Cone 6 Glazes can be very sensitive to cooling rates.  Artists can now use 

the Ramp/Hold programming mode to control whether the kiln vent is on for each segment of the fir-

ing program.

Glass Artist

 - Artists who fire glass want to cool quick and hold steady.  With the EnviroLink they can 

program the vent to come on when crash cooling and then turn off during annealing when they are try-

ing to hold the temperature steady.

Содержание EnviroVent

Страница 1: ...he EnviroLink which provides power to the device A red indicator light signals that there is power to the EnviroLink and a green indicator light signals that the EnviroVent is in the ON position The EnviroLink will only work with 600 and 700 series Skutt GlassMaster and KilnMaster Controllers manufactured after January 1st of 2001 The EnviroLink is rated to cycle components up to 12 amps Consult t...

Страница 2: ... the controller s connector that is closest to the round black speaker at the top of the board This is marked Output 4 on the KM 600 and GM 600 boards not marked on some GM 700 boards Screw the controller back in place Plug the EnviroLink into a 120V outlet and your vent into the EnviroLink Plug in the kiln The installation is complete Be sure the in line toggle switch on the vent is in the on pos...

Страница 3: ...nt setting either OFF or ON To change the setting toggle it with the 1 key and press ENTER to select that setting OP b Option B When Option B is selected Output 4 will turn on only during segment 6 of a GlassFire Mode program This program is designed to limit a fan from coming on when fusing extremely sensitive large pieces of glass It will come on between the process temperature and the annealing...

Страница 4: ...iln cools to 150 F When a Ramp Hold program is entered it will ask whether you want the fan or other accessory on for each segment you program After you enter the hold time for each segment the display will show FAN along with the number of the segment you are programming Alternately it will flash the current setting either OFF or ON To change the setting toggle it with the 1 key and press ENTER to...

Страница 5: ...g either OFF or ON To change the setting toggle it with the 1 key and press ENTER to select that setting OP C Option C When Option C is selected Output 4 does not come on during any portion of a ConeFire Mode program When a Ramp Hold program is entered it will ask whether you want the fan or other accessory on for each segment you program After you enter the hold time for each segment the display ...

Страница 6: ...RE TAB TEXT HERE E N V I R O L I N K M A N U A L REV 04 24 06 ENVIROLINK MANUAL CONTINUED To EnviroLink Marked on 700 Board Marked Output 4 on 600 Board Marked Center Tap on 600 and 700 Board 600 and 700 Circuit Board Does not exist on 600 Board Red Black ...

Отзывы: