SKS-Kinkel Elektronik GmbH
300092 Extended video compact power supply
EN
Support Hotline: +49 (0) 2661 98088-112
Support E-Mail: [email protected]
Version No. 2-0
Document No. 97009701
18
2.2
Features
3
Supply of up to 96 video indoor stations (without parallel operation) and up to 8 cameras
3
If indoor stations are operated in parallel the maximum number of indoor stations in the system is reduced
3
Can be used to establish floor lines
3
Suitable for connecting a line extension
3
The Video Compact Power Supply is short-circuit-proof and protected against overload
3
Nominal input voltage: 207 to 253 VAC/50 Hz
3
Working temperature: -5 °C to +45 °C
3
Protection type: IP20
2.3
Scope of Delivery
3
Extended video compact power supply
3
Two 10-pole terminals
3
Two 75 ohm terminating resistors
3
Installation instructions
2.4
Storage and Transport
Transport only in original packaging, store in a dry and cool place.
2.5
Care instructions
Just clean the device unit with a soft cloth, moistened with a mild soap solution. Dry cleaning, aggressive detergents
and abrasives may damage the surface.
2.6
Modification
A modification (alteration or conversion) of the Video Compact Power Supply is not allowed.
2.7
Safety
Electrical shock hazard to persons. Danger of burns, damage to device and malfunctions.
VDE 0100 and VDE 0800 guidelines must be complied during installation. (Germany)
Counter measures:
3
Before beginning any work, deactivate and disconnect all energized electrical wires.
3
Secure the switched off/disconnected lines against erroneous reconnection.
3
Use a measuring device to make sure that the wires are de-energized.
3
Cover up any adjacent, energized or conducting components.
3
All work and all electrical connections must comply with the national provisions for the country in question and
must be performed by appropriately trained personnel.
Mounting, installation, reparation and initial setup must be carried out by qualified elec
-
tricians only! When working on systems with 230 V alternating voltage the safety require-
ments of DIN VDE 0100 must be complied with.
The SKS planning guide (can be downloaded from www.sks-kinkel.de) must be followed during installation!