17
Support Hotline: +49 (0) 2661 98088-112
Support E-Mail: [email protected]
Version No. 1.0
Document No. 97016900
SKS-Kinkel Elektronik GmbH
30008701 Diagnostic tool
EN
A = BUS command
B = BUS voltage
C = Signal level in % (ideal > 90%)
D = Frequency (ideal 22,3 kHz)
E = Number of pulses at the
receiver‘s input between two
BUS commands
1 = General Reset
Resetting the system or rather the BUS line (idle mode)
2 = HTSNr
:
Door station no., from which the door call was sent (1 to 8)
3 = HR1
Door call 1 with call address A1
4 = SpBer
:
Ready to speak, i. e. the receiver has been picked up at the indoor
station with call address A1
5 = TOE1
Door opener command has been sentfrom the indoor station with
the call address A1
6.2.2
Overview of possible commands
Display
BUS command
Description
General Reset
General reset
After this the systems changes into idle mode
HR1
Door call 1
HR2
Door call 2
SpBer
Ready for speaking
Speaking connection activated
Aufgel
Receiver put down
Speaking connection ended
TOE1
Door opener 1
Door opener command sent
TOE2
Door opener 2
Door opener command sent
Conc0
Concierge 0
Special command 1, the receiver has been put down
Conc1
Concierge 1
Special command 2, the receiver has been picked up
Licht
Light command
KnaEin
Crackling sound on
KnaAus
Crackling sound off
KamUm
Switching camera command
Only for 6-wire systems
HTSNr
Door station number
Door station number from which the command has been
sent
KamNr
Choose camera number
AktVer
Extend active time
Only for 6-wire systems, extends the video compact
power supply‘s active time
DisplOn
Display at indoor station active
Determins the number of active displays at indoor sta-
tions in the system
UnbekBefehl
Command unknown