21
Support Hotline: +49 (0) 2661 98088-112
Support E-Mail: [email protected]
Version No. 2.0
Document No. 97004702
SKS-Kinkel Elektronik GmbH
300022 Switching actor
EN
Step
Description
1
If unsure whether call addresses have been programmed into the Switching actor or which
ones, we recommend to delete all call addresses from the Switching actor‘s storage space
before you start.
2
Carefully open the Switching actor‘s housing.
3
Set the call address of the indoor station at DIP switch S2, that you want to program into the
Switching actor.
4
Keep hold of the programming key inside the housing of the Switching actor for 5 seconds
until LED 2 lights up for 2 seconds.
5
After you let go of the programming key, LED 2 shows which storage space has been used
for the call address by flashing accordingly (every 0.5 seconds). For the first call address it
flashes once, for the second twice, for the third three times and so on.
6
To program further call addresses repeat steps 3 to 5.
If you try to program in another call address when the storage space is full, LED 2 does not light up for 2 seconds
but flashes rapidly instead (20 x, every 0.1 seconds).
Attention
A maximum of 30 call addresses can be stored in a Switching actor. If call address-
es are to be changed or overwritten, all call addresses must be deleted first.
8.3.2
Deleting of call addresses
Single call addresses can not be deleted. All call addresses are always deleted together. To do so keep hold of
the programming key for 10 seconds. After 5 seconds LED 2 lights up for the first time. Keep hold of the key until
LED 2 lights up for a second time.
Now all call addresses are deleted.
9 Technical Data
Electrical data
Voltage supply (terminals a+/b-)
19 to 25 VDC
Current draw on standby
8 mA
Current draw with relay switched
20 mA
Maximum current draw
32 mA
Load units on standby/not active
1
Load units with switched relay/active
3
Relay contact
10 A (250 VAC/30 VDC)
Range of switching time
1 to 655 seconds
General data
Temperature
-10 °C to +55 °C
Humidity
20% to 90%, non-condensing
Housing
DIN rail Housing
Measurements (width x height x depth)
70 x 91 x 70 mm (4TE)
Protection type
IP20