4 DIP switches
4.1
DIP switch S1
DIP switch S1 serves to set the operating mode of the two relays K1 and K2, here the first switch determines the
function of relay K1 and switches 2 to 4 the function of relay K2.
Settings for relay K1
DIP switch position
Description
ON
Concierge call
for the time set at P1, from all indoor stations
ON
Door or internal call command
for the time set at P1, from all indoor stations or rather from up to 30 indoor stations
programmed into the Switching actor
Settings for relay K2
DIP switch position
Description
ON
Without any function for relay K2
ON
Light command
for the time set at P2, from all indoor stations
ON
Door or internal call command
for the time set at P2, from all indoor stations or rather from up to 30 indoor stations
programmed into the Switching actor
ON
Do not use
ON
Internal call command
for the time set at P2, from all indoor stations or rather from up to 30 indoor stations
programmed into the Switching actor
ON
Light command
with relay K2 as surge relay, i. e. the light is switched on when operated, if operated
again it is switched back off, from all indoor stations
ON
Concierge call command
for the time set at P2, from all indoor stations or rather from up to 30 indoor stations
programmed into the Switching actor
ON
Door opener command
for the time set at P2, from all indoor stations or rather from up to 30 indoor stations
programmed into the Switching actor
LED status
Description
LED flashes 20 x for 0.5 seconds
after the storing process
Number of flashing shows the storage place used for the latest call address,
flashing once = storage place 1, flashing twice = storage place 2, flashing
three times = storage place 3 and so on, here a maximum of 30 storage spac-
es can be used
LED on after deleting
Deleting successful