DOL 100 digital box
Technical User Guide
15
4.7 Cable Plan
Power supply
Power supply
CAN bus cable
max. 400 m
(D)
(A)
(B)
(C)
(E)
(F)
(G)
(A)
Power supply to the controller, two-wire cable including earthing contact.
(B)
Max. 400 m CAN bus communication cable between the DOL 100 digital 8l/16l box and the controller. The
CAN bus cable connecting all units of the system may not exceed 400 m.
(C)
Power supply to the DOL 100 digital 8I/16I box, two-wire + earthing contact.
(D)
Two-wire control cable to the water meter.
(E)
Three-wire power supply and control cable to DOL 192 12-20 egg counter.
(F)
Two-wire control cable to DOL 192 30-75 egg counter.
(G)
Four-wire power supply and control cable to capacitive sensor.
Содержание DOL 100