DOL 100 digital box
14
Technical User Guide
4.6 Setting up the DOL 100 in the controller
Make sure the CAN protocol is set to CANopen.
Technical | Setup | Installation | I/O Modules | CAN protocol
Select number of DOL 100.
The DOL 100 8I box supports up to 8 water meters, egg counters or
capacitive sensor.
The DOL 100 16I box supports up to 16 water meters, egg counters or
capacitive sensors.
The software supports up to 13 I/O modules. DOL 100 is counted in as
one module.
Technical | Setup | Installation | I/O Modules | Extra I/O modules
Here you see the CAN bus address (CAN ID) and if it is connected.
Select number of water meters
Technical | Setup | Installation | Production | Water meter
Select number of egg counters
Technical | Setup | Installation | Production | Egg counter | Egg
counters installed
The DOL 539/535 installation menu specifies which connection ter-
minal numbers and in which DOL 100 box the water water meters must
be connected.
For correct connection of the items, see the menu
Technical | Setup |
Show connections
I/O#1 N13
= DOL 100 box no. 1, connection terminal N13.
I/O#3 N28
= DOL 100 box no. 3, connection terminal N28.