Skov DOL 100 Скачать руководство пользователя страница 1

DOL 100 digital box

Technical User Guide

604336 • 2018-08-07

English 

For other language variants of this document we refer to:

Español 

Para otras variantes del idioma de este documento, visite:

Français 

Pour les versions dans d'autres langues de ce document veuillez consulter:

http://docs.skov.com/1174

Содержание DOL 100

Страница 1: ...2018 08 07 English For other language variants of this document we refer to Espa ol Para otras variantes del idioma de este documento visite Fran ais Pour les versions dans d autres langues de ce docu...

Страница 2: ......

Страница 3: ...is manual may be reproduced in any manner whatsoever without the expressed written permission of SKOV A S Every effort has been made to ensure the accuracy of the information contained in this manual...

Страница 4: ...AN bus coupler 10 4 3 1 LED indication on the CAN bus coupler 11 4 4 Nano I O module digital 8l 12 4 5 Connection in DOL 100 13 4 6 Setting up the DOL 100 in the controller 14 4 7 Cable Plan 15 4 8 Ci...

Страница 5: ...the climate controller The DOL 100 converts the signal into digital signals and transmits them to the controller using CAN bus commu nication DA 100 digital is available in two variants Connect up to...

Страница 6: ...used with the data network module 132244 and a CAN bus cable 130121 130128 2 1 Accessories 132244 Data network module w CAN bus Always use the data network module when using external CAN bus com munic...

Страница 7: ...ng Guide 3 1 Recommended tools Below follows a list of tools recommended for installation of the DOL 100 Item Description Cordless drill Screwdriver bits Utility knife Multimeter Tape measure Side cut...

Страница 8: ...DOL 100 digital box 8 Technical User Guide 3 2 Mounting on Wall Mount the DOL 100 digital box on the wall us ing four screws...

Страница 9: ...dard EN 60204 1 and any other EU standards that are applicable in Europe The installation of a power supply isolator is required for each motor and power supply to facilitate voltage free work on the...

Страница 10: ...AN ID The DOL 100 must have a specific CAN ID for the controller to communicate with it The address of the individual DOL 100 corresponds to the address in the controller in the menu Technical Setup I...

Страница 11: ...OK B Internal CAN bus RX Green ON receiving data Internal CAN bus TX Red ON transmitting data C External CAN bus RX Green ON receiving data External CAN bus TX Red ON transmitting data D CPU RUN Gree...

Страница 12: ...TERM CAN bus termination The jumper is mounted on the I O module furthest away from the CAN bus coupler B CAN ID Jumper setting on I O module 1 Jumper setting on I O module 2 C Terminals 24 V DC N11 N...

Страница 13: ...N bus connection see dimensions below CAN_H brown CAN_L white CAN GND green Strip the cable so the shield can be connected to the DOL 100 when mounting in the connection terminal As illustrated by the...

Страница 14: ...one module Technical Setup Installation I O Modules Extra I O modules Here you see the CAN bus address CAN ID and if it is connected Select number of water meters Technical Setup Installation Product...

Страница 15: ...tween the DOL 100 digital 8l 16l box and the controller The CAN bus cable connecting all units of the system may not exceed 400 m C Power supply to the DOL 100 digital 8I 16I box two wire earthing con...

Страница 16: ...DOL 100 digital box 16 Technical User Guide 4 8 Circuit Diagram 4 8 1 DOL 100 and water meter...

Страница 17: ...DOL 100 digital box Technical User Guide 17 4 8 2 DOL 100 and DOL 192 12 4 8 3 DOL 100 and DOL 192 20...

Страница 18: ...DOL 100 digital box 18 Technical User Guide 4 8 4 DOL 100 and DOL 192 30 75 4 8 5 DOL 100 and capacitive sensor...

Страница 19: ...19 5 Cleaning The DOL 100 box is maintenance free but should be kept free of litter and dirt Clean the product with a cloth that has been wrung out almost dry in water and avoid using high pressure c...

Страница 20: ...I 16I box and water meter egg counter capacitive sensor in the controller see section Setting up the DOL 100 in the controller 14 No CAN bus communication con nectivity with the DOL 100 digital 8l 16l...

Страница 21: ...nals 8 digital Low V 6 High V 12 Input impedance kOhm 24 Max input frequency Hz 500 Puls width min ms 1 Outputs for power supply to egg counter and capacitive sensor Voltage V dc 24 Max current A 1 9...

Страница 22: ......

Страница 23: ......

Страница 24: ...604336 2018 08 07 en Made in Denmark SKOV A S Hedelund 4 Glyng re DK 7870 Roslev Tel 45 72 17 55 55 www skov com E mail skov skov dk...