DA 600 LPC • DA 600 • ECT 632-6 • DCT 632-6
Technical User Guide
13
3.3 Safety distance
If the distance from the floor to the fan blade is less than
270cm, mounting a protective mesh in the inlet bell
mouth may be required to meet the statutory require-
ments.
3.4 Position of motor controller/frequency converter
Motor controller/frequency converter must not be built-in
or covered and must be mounted on a solid, level sur-
face.
In order to uphold protection classifications, access and
cooling, the motor controller/frequency converter must
be positioned as shown in section
for the motor controller/frequency converter [
3.5 Mounting distances for the motor controller/frequency converter
In order to ensure access of cables and cooling of the
motor controller/frequency converter, the distances to
the surroundings must be met.