DA 60-820
Technical User Guide
37
3.19 Mounting adapter on the duct
Remove the 4 protuberances on the duct.
Mount 4 6x23 screws from adapter and into
the duct.
Drill up the next 4 holes in the adapter. Drill
size 6.2mm.
Mount 4 bolts M6x25 from inside duct and
out into the adapter.
Mount 4 washers and nuts on the outside of
the adapter.
3.20 Mounting the intermediate and bottom plate
50 mm
Mount 2 nuts M8 and washers.
Adjust the distance so that there is 50mm be-
tween the washer and the guide rod end.
Tighten the 2 nuts against each other.