Cleaning the condenser coil
The condenser coil MUST be kept clean for efficient and reliable
operation. To ensure trouble free performance, it is recommended
that on a regular basis the cabinet be isolated from mains power
supply and a vacuum cleaner used to remove dust and fluff from the
condenser coil.
The condenser coil should be brushed clean once a month, and
blown clean by qualified service personnel, every six months. The
condenser coil is situated behind the sign unit. To access the
condenser coil:
1. Disconnect the cabinet from the mains power supply.
2. Loosen the sign retaining clip on the top of each side panel.
3. Lift the sign unit up, to disengage from the sign sides.
4. Disconnect the sign ENSTO plug from the unit junction box
socket, and remove the sign unit from the cabinet.
SERVICE INSTRUCTIONS
4
Figure 26: Condenser Coil
Condenser Coil
Evaporator Box
Unit Handle
Controller Cables