Skope S4 EVO Скачать руководство пользователя страница 3

instruction sheet 

 

 

 

  

 

 

Email: [email protected] Website: www.skope.com 

New Zealand Freephone: 0800 947 5673, Australian Freephone: 1800 121 535 

 

SKOPE INDUSTRIES LIMITED 

 

Page 3 of 5

 

PRN80331 Rev. 1.1 Jul. 2022

 

Rework Instructions 

SK-2, B-2, CC, CL, and BB Variants 

Remove the QC connectors from the controller interface wiring and connect the S4 controller as shown 

below. 

  Separate the lighting/heating from the fan (T1-3), and hardwire the lighting/heating to 

phase (T1-2). 

  For switched lighting models only: wire the heater elements to phase and the lighting back 

to the controller as shown in the diagram. 

 

 

 

 

 

 

 

Отзывы: