Programme the EZY set number on the controller
Follow the steps below to select or change the EZY number.
1. Press and hold the
SET
key for 3 seconds until the
display shows “PS”.
2. Press the
SET
key to access the password
parameter. “
0
” is displayed.
3. Use the
ES
(up) and
Light
(down) buttons to
display the password ‘
22
’ (default password).
4. Press the
SET
key to confirm the password. The
display shows ‘
PS
’.
5. Use the
ES
(up) and
Light
(down) buttons to
navigate to the ‘
EZY
’ parameter.
6. Press the
SET
key to access the parameter.
7. Select the EZY number (see table on page 1).
8. Press the
SET
key to save the parameter.
9. Press and hold the
SET
key for 3 seconds to exit
the parameter settings.
CAUTION
The controller ships with EZY set 0 active. No changes are required to enable this
set. If another EZY set is active and set 0 is required, you must perform a factory