Lighting

This chiller is designed for use with LED tubes and is not compatible with 
fluorescent tubes.

Interior Light

The cabinet interior is lit by two 19 Watt T8 LED tubes (Ø26mm x 1200mm), 
which can be replaced without moving shelves or removing product.

To replace the cabinet interior light

IMPORTANT

DO NOT

 use fluorescent tubes.

1. Remove the front panel and isolate the chiller from the mains power supply 

(see previous page).

2. Remove the diffuser by squeezing it until it is released from the aluminium 

housing, and then push the diffuser out of the way.

3. Rotate the LED tube until 

the pins on the ends of the 
tube align with the slots, 
then slide it out.

4. Fit a new LED tube. 

Note: 

the pointer at each 

end of the tube should be 
set to the “0” position.

5. Refit the diffuser by slipping the back section into the housing, then 

squeezing and snapping the front section of the diffuser into place as you 
work down the length of the light.

Pins

Lamp Holder

LED Tube

(partially removed)

Содержание B1200-2

Страница 1: ...B1200 2 B1200G 2 User Manual MAN10364 Rev 3 3 Mar 2014 B1200G 2 SKOPE Two Door Vertical Chiller B1200 2 no sign G12EV X5621 B1200G 2 lit sign G12EV...

Страница 2: ...land SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purcha...

Страница 3: ...om Shelves 6 Wire Shelves 6 2 Operation Automatic Start Up 7 Loading Product 7 EMS Controller Operations 8 Introduction 8 Self Learning 8 Motion Sensor Door Switch 8 Faceplate 9 Temperature Setpoint 1...

Страница 4: ...ssential to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If...

Страница 5: ...from overflowing Ventilation Ensure there is always at least a 50mm gap around the back top and underside of the cabinet Keep the ventilation slots in the front panel clear at all times never store ca...

Страница 6: ...may be fitted at different heights to suit various products Each shelf is held in place with four shelf clips which engage in the shelf support strips The support strips are numbered for easy location...

Страница 7: ...elves because this might stop the doors from shutting or even break something Item Activity Condenser Fan The condenser fan starts when the chiller is plugged in Lighting The lights that illuminate th...

Страница 8: ...t shopping activity and updating itself A service agent is not required if the store hours change or you disconnect the power to move the chiller The EMS Advanced controller continuously collects data...

Страница 9: ...the compressor light green when on 5 LED for the evaporator fan green when on 6 LED indicating perishable mode red when on See page 10 for more information 7 LED linked to the motion sensor and flash...

Страница 10: ...ture is moderated the lights switch off and the fans cycle on and off during standby periods resulting in maximum energy savings Follow the steps below to change between perishable and non perishable...

Страница 11: ...pen over two minutes an alarm sounds but stops when the door closes again If the door remains open five minutes such as when loading product then the alarm stops and the EMS Advanced controller turns...

Страница 12: ...olated from the power supply before cleaning Condenser Coil To ensure trouble free performance we strongly urge monthly cleaning with a soft brush to remove dust and fluff A more thorough cleaning is...

Страница 13: ...late the chiller from the mains power supply see previous page 2 Remove the diffuser by squeezing it until it is released from the aluminium housing and then push the diffuser out of the way 3 Rotate...

Страница 14: ...of the sign assembly 6 Loosen the two outside screws vertical slot screws and slide the lampholder brackets and LED tube to the bottom of the vertical slots 7 Rotate and remove the failed LED tube 8...

Страница 15: ...higher than expected Unit operating too hot Clean the condenser coil see page 12 Ensure the cabinet has good ventilation around the refrigeration unit see page 5 Ensure the cabinet is in a cool spot...