14
Electronic Controller
Service Manual
SKOPE TME ActiveCore
cabinet setpoint can be adjusted between 1°C and 15°C for other specialist
applications if required (see below).
SKOPE do not recommend that the setpoint be changed unless it is
absolutely necessary, and then only by small increments at a time.
To view and adjust the temperature setpoint
Parameters
Follow the steps below to access the locked parameters.
To access the locked parameters
1. Press and hold the
set
button for 3 seconds until
PS
is
shown on the display, indicating entry into the controller
settings menu.
2. Press the
up
or
down
button to scroll the menu until
St
is shown on the display.
3. Press the
set
button. The current setpoint value is shown on the display.
4. Press the
up
or
down
button to increase or decease the setpoint value to the
required temperature.
5. Press the
set
button to temporarily save the setpoint value.
6. Press and hold the
set
button for 3 seconds to permanently save the setpoint
value and exit the controller settings menu.
1. Press and hold the
Set (mute)
button for 5 seconds until the display shows
‘
PS
’.
2. Press the
Set (mute)
button to access the password parameter, ‘
0
’ is
displayed.
3. Use the
Energy Save (up)
and
Light (down)
buttons to display the
password ‘
22
’ (default password).
4. Press the
Set (mute)
button to confirm the password. The display shows
‘
PS
’.
5. Use the
Energy Save (up)
and
Light (down)
buttons to scroll the parameter
codes and locate the required parameter.
Parameter categories can be identified by the initial symbol or letter of the
code, and the icon displayed on the electronic controller faceplate:
6. Press the
Set (mute)
button to display the value associated with the
parameter code.
7. Use the
Energy Save (up)
and
Light (down)
buttons to increase or
decrease the value of the parameter.
Continued over page
Category
Initial
Icon
Probe parameters
/
-
Control parameters
r
-
Compressor parameters
c
Defrost parameters
d
Alarm parameters
A
Fan parameters
F