ESN200 Operation and Installation Manual
ESN200 Operation and Installation Manual
Chapter: CONFIG software setup
Chapter: CONFIG software setup
ES
Setup
Transducer setup
Once connected the system requires the installer to identify which transducer is connected to
which of the 2 connectors. System required 1 approved transducer to be installed (currently
200/50/38 kHz), the second can be any transducers.
The approved transducer should be set to primary, and this is the transducer that reports the
standard DPT output messages.
Both connectors can have a transducer fitted. To select the correct fixture, start the system and go
to the config menus, and then the ES setup.
Here you can select the transducer menu and by clicking on the transducer connector port you
can move the transducer to the appropriate area of the vessel, and select the transducer, by part
number. This will change the parameters to match your transducer.
If you are not using a standard transducer, then select other, and the frequency, max power and
max expected range can be set for that
Selectable transducer types
Part number Type
Approved
for use
ETN050
50 kHz of types ETN50(X)G, ETN50(X)T
Yes
ETN200
200kHz of types ETN200(X)T
Yes
ETN200S
200kHz of type ETN200S(X)G, ETN200S(X)G
Yes
ETS50200
Combined 50 and 200kHz of types ETS50200(X)G and ETS50200(X)
T (Limited to 50% Power (50kHz) and 70% power (200kHz)
Yes
ETN038
38 khz
Yes
8B-200
Furuno 200kHz Transducer
Yes**
S-50-18
SIMRAD 50kHz (500W max)
No
Other
Any other
No
ETN024
24kHz
No
** The named transducers have BV reviewed tests, proving they work to specification with the system.
Standard transducers have the required values set.
‘Other’ transducers can change values in the settings. See section ‘Other Transducers’
At least 1 installed transducer should be within the SKIPPER approved list.