SKIPPER
Electronics AS
EML224N Operation and Installation Manual
Edition: 2020-02-05
Chapter: 2. Operation
Page 14 of 64
Fig. 2.5 A. Screen Com, Menu 1
Soft
key
Name
Range/value Default value
Description
Activate
with hidden
button
1
MENU
1 - 2
1
Chosen menu number 1.
2
COM
1 - 2, sensor
1
Serial port number referred by other keys.
3
COM ERROR
Reset
Reset field for COM errors. The program
memorizes the latest occurred NMEA input error
for further analysis. By using this softkey, it is
possible to reset the error.
4
MESSAGE
VHW, VLW,
VLW IEC07,
VBW, MTW,
NMEA message selector. Each message may be
controlled individually by soft key 5.
5
OUTPUT
On/off
VHW: on
VLW: off
VLW IEC07: off
VBW: on
MTW: off
Setting for the message in soft key 4 [On/Off]
Note:
To configure the serial output of the system,
go through all the messages by pressing soft key
4 and set on/off value of the soft key 5 to disable/
enable a message as required.
6
DISPLAY
Input, off,
output
Input
Selects the information (received from the
external source or transmitted by the EML224) to
be displayed in the “TEXT” window (left side).
• Input
: Displays information received from
external source.
• Output
: Displays information transmittet by
EML224.
• Off
: None.