SKIPPER DM-D100 Installation manual Dolog replacement
Page 2 of 11
Date: 2021.03.16
INTRODUCTION
This document describes how to install a SKIPPER DL2 100mm sensor into an excisting
DOLOG 2X (DOLOG 21/22/23) tank.
The Rev 01 of KIT-DOLOG-M1-SA is a plastic adaptor.
The sensor replacement is recommended to be performed in dry dock. It is possible to
replace the sensor with vessel afloat.
The replacement will require new DL2 Operator unit, transceiver unit, junction box and
sensor. For DL2 Operator unit and Transceiver unit installation instruction, please see DL2
installation manual.
This procedure will mainly cover replacement of DOLOG sensor.
DL2SDR-SA consist of:
• DL2SDR-ZB Sensor DL2. 40m cable with sealed cable end
• KIT-DOLOG-M1-SA Kit DOLOG 2X
• KIT-DOLOG-T1-SA. Kit Mounting tools DOLOG 2X
TABLE OF CONTENTS
Prepare sensor for installation
Install sensor into dolog tank
• This revision of manual is valid for Rev 2 of KIT-DOLOG-T1-SA with improved
grounding contact between the sensor and the sea water. (Through Screw M10x140,
ZOA-01215, Item 12)