Name of the Components
Side View
Front View
Evaporator
Glass Door
Digital
Control
Castor
Lamp
Evaporator Motor
Condenser
Motor
Compressor
Adjustable Leg
Keyhole
for Door Lock
Cover
3
Shelf
Страница 1: ...ODEL SGF 6 www skipio com au Y E A R Sydney Head O ce T 61 02 8798 5061 5283 5581 F 61 02 8798 5707 Please read this manual thoroughly prior to use Please make sure that it is an actual breakdown by r...
Страница 2: ...lation Procedures 7 Installation 8 Temperature Adjustment Precautions prior to use The inner temperature may change due to frequent use of the doors the amount of stored food and surrounding condition...
Страница 3: ...of the Components Side View Front View Evaporator Glass Door Digital Control Castor Lamp Evaporator Motor Condenser Condenser Motor Compressor Adjustable Leg Keyhole for Door Lock Compressor Cover 3 S...
Страница 4: ...the power plug Grounding required to prevent an electric shock Warning Prohibited Prohibited Prohibited Grounding Prohibited Wet hand prohibited Do not plug into a power board with other equipment an...
Страница 5: ...n a window for ventilation Cautions Placetheunitwherethereisno inhabitationofanimalssuchasmice They can gnaw on electric wires If strange sounds smells or smoke is detected immediately disconnect the...
Страница 6: ...e an injury Prohibited 5 min AC 240V with ground prong As it is 240V there is no need to ground Even AC 200V sockets with a hole for grounding may not have ground wires connected inside the building s...
Страница 7: ...here water can be splashed on to the unit there are a lot of dusts or highly humid If the unit is installed where it is humid or there is contact with water the unit can get rusty and it can also caus...
Страница 8: ...et desired temperatures TemperatureSetButtons Please use the Down button or Up button to set your desired temperature Please wait 3 seconds after setting your desired temperature for the desired tempe...
Страница 9: ...emove objects that are blocking the exhaust 2 Please move the unit away for walls and objects Unit needs 10cm gap 2 Is the unit too close to a wall or an object 1 Is the unit level or is on a weak sur...
Страница 10: ...to the room temperature being too different to the temperature inside the unit door s being open for a long time or if there is a lot of food inside without lids 10 Frequently Asked Questions Hear liq...
Страница 11: ...olyurethane Cyclopentane CFC Free Refrigerant Lamp Cooling Type 240 50 1 Swing 1 door Heating Glass Temperature Control Type Insulation Type Amps A Weight Kg Voltage V Hz Ph Door type Compressor HP of...
Страница 12: ...www skipio com au Melbourne Branch Sydney Head O ce T 61 02 8798 5061 5283 5581 T 61 03 8405 3359 9408 4081...