background image

OPERATION

1.

Use the following procedure to test the system before each use.

a.

Press Battery-Test button. If alarm is weak or fails to  sound,

replace 9-volt battery and press button again. If alarm is still weak or

fails to sound, discontinue use of alarm.

b.

Seat patient and secure belt by placing the magnet (located

under red loop) over metal strip. (Illustration 3) Battery indicator light

should flash. If light fails to flash, replace battery and make certain that

the telephone-style plug is securely connected to the alarm unit. Retest.

If battery indicator light still fails to flash, discontinue use of system.

c.

Open magnetic closure. Alarm will sound. Secure closure.

Alarm will silence itself. It is now in the monitoring mode. If alarm fails

to sound when magnetic

closure is opened, check

plug connection and/or

replace battery. Retest. If

alarm again fails to

sound, discontinue use

of system.

2.

Select high or low vol-

ume.

3.

Alarm is activated

when patient opens the

magnetic closure. Press

the Auto-Reset button to

silence the alarm. The

alarm is now in stand-by

mode. Do not secure the magnetic closure when the system is not

being used to monitor a patient. Securing the closure will cause the

battery indicator light to flash and shorten battery life.

4.

The alarm will automatically go into the monitoring mode when the

magnetic closure is secured.

There is no on/off switch.

5.

After the closure is secured, adjust the belt to a proper fit around

patient’s hips.The wheelchair user may easily release the belt by plac-

ing his/her hand through the red loop and pulling up on the end.

with E-Z Release Velcro

®

Belt Alarm

29 Wells Avenue  

914-963-2040

Yonkers, NY 10701

800-431-2972

Model #   Description  

Guarantee Unit

909393

E-Z Release Velcro

®

Belt Alarm One Year

Each

INSTALLATION

1.

Remove the rearmost screws

from the left and right sides of

the wheelchair seat. Insert the

screws through the grommets

on the ends of the two belt sec-

tions. Refasten screws to the

wheelchair. (Illustration 1)

2.

Place the telephone-style

connector cord through the

space between the wheelchair

seat and backrest. Make certain

that it is away from wheels and

other moving parts.

3.

Insert telephone-style plug into

Modular Receptacle on right side

of alarm. (Illustration 2) Alarm will

sound. Press Auto-Reset to

silence alarm.

Advanced design for nursing and therapy.

TM

Alarm system made in China. Instructions printed in USA.

Visit us online

at Skil-Care.com

1

2

3

MultiPro/ChairPro E-Z Releas.Qk  4/3/06 9:38 AM  Page 1

Mounting Bracket

LED

A

B

C

D

E

F

Fig. 1

Fig. 2

Model # Description

Size

Unit

909371

ChairPro E-Z Release

Universal Each

Belt Alarm

GUARANTEES

1.

The ChairPro E-Z Release Belt Alarm Unit is replace-

ment guaranteed for one year following the date of pur-

chase.

2.

The E-Z Release belt with Velcro

®

closure and mag-

netic switch is replacement guaranteed for one year fol-

lowing the date of purchase.
These guarantees cover defects in materials and work-

manship under conditions of normal use. Please return

defective part to dealer from whom it was purchased. The

dealer will send the defective part to Skil-Care and

arrange for shipment of a replacement.

PURPOSE

The ChairPro E-Z Release Belt Alarm is a non-restrictive

wheelchair safety belt with integral magnetic alarm

switch. It is designed to alert caregivers when a patient

attempts to leave or has fallen from the wheelchair.

CAUTIONS

1.

The ChairPro E-Z Release Belt Alarm is not a substi-

tute for proper supervision. Fall-risk residents/patients

should be monitored regularly.

2.

Check battery each time alarm is used. If weak,

replace the 9-volt battery.

3.

LED should flash when the magnetic switch is

engaged. If LED fails to flash, check battery. Replace if

necessary. If LED fails to flash after battery has been

replaced and the plug is determined to be properly con-

nected, discontinue use of device.

29 Wells Avenue  

914-963-2040

Yonkers, NY 10701

800-431-2972

1.

Insert enclosed cord

loop through bracket

hole. (Illustration B)

2.

Hang from wheel-

chair push-handle

(Illustration C)

B

C

Continued on reverse side.

R

es

traint-Fr

e

e

   

 

T

M

Cord Loop

INSTALLATION

Alarm Unit

You may choose one of the following two ways to attach

the alarm unit to the wheelchair.

Mounting Bracket
1.

Remove the second-

from-top screw from either

the left or right side of the

wheelchair backrest.

2.

Remove grommet from

screw, place the screw

through hole on alarm unit

mounting bracket, and

fasten screw to

wheelchair backrest.

(Illustration A)

A

ChairPro Safety Alarm

Auto-Reset

Battery

Test

Test battery before each use. If 
weak, replace with 9-volt battery. 
LED must glow when alarm is in 
use. If not, replace battery.

High

Low

Mini-Phone 

Plug

Modular

Receptacle

Mounting Bracket

LED

Alarm unit made in China. Instructions printed in USA.

E-Z RELEASE BELT ALARM

GUARANTEES 

1. The E-Z Release belt with Velcro

®

 closure and magnetic switch is 

replacement guaranteed for one year following the date of purchase.

These guarantees cover defects in materials and workmanship under

conditions of normal use.  Please return defective part to dealer from whom

it was purchased.  The dealer will send the defective part to Skil-Care and 

arrange for shipment of a replacement.

PURPOSE

The ChairPro E-Z Release Belt Alarm is a non-restrictive wheelchair safety

belt with an integral magnetic alarm switch.  It is designed to alert caregivers 

when a patient attempts to leave the wheelchair.

CAUTIONS

1. The ChairPro E-Z Release Belt Alarm is not a substitute for proper 

supervision. Fall-risk and wander-risk patients or residents should 

be monitored regularly.

2. Check battery each time alarm is used. If weak, replace the “AA” battery.

3. LED should flash when the magnetic switch is engaged.  If LED fails to 

flash, check battery.  Replace if necessary. If LED fails to flash after battery

has been replaced and the plug is properly connected, discontinue use 

of device.

INSTALLATION

Alarm Unit

You may choose one of the following two ways to attach the alarm unit to 

the wheelchair.

Attachment of Alarm Unit

Mounting Bracket

1. Remove the second-from-top screw from either the left or 

right side of the wheelchair backrest.

2. Remove grommet from screw, place the screw through 

hole on alarm unit mounting bracket, and fasten screw to 

wheelchair backrest. (Illustration A)

1. Insert enclosed cord 

loop through bracket hole. 

(Illustration B)

2. Hang from wheel-

chair push-handle 

(Illustration C)

SEAT BELT INSTALLATION

WHEELCHAIR BELT INSTALLATION (Grommet)

1. Remove the rearmost screws 

from the left and right sides of the 

wheelchair seat. (Illustration D)

2. Remove the grommets from 

the screws, place screws 

through the grommets at 

the ends of both belt

sections, and refasten the 

screws to the wheelchair seat. 

(Illustration E) 

3. Select either hole in

belt depending upon desired 

length, closer holes will yield 

a shorter length, 

holes closet to the end 

will yield a longer length.

4. Attach the two “spade” 

connectors on the connector 

wire to those on the seat belt. 

(Illustration F)

Note, that for removable arm

wheelchairs it may be easier

to install the belt after the arm 

is removed.

5. Place connector cord through the space between 

the wheelchair seat and backrest. Make certain that 

it is away from wheels and other moving parts.

WHEELCHAIR BELT INSTALLATION (Loop)

1. UnThread the loop end of the belt.

2. Remove the arm of the wheelchair 

    (if removable arm)

3. Lay belt on 

wheelchair while 

holding loop end, 

place loop end around 

the bottom of the 

wheelchair (Fig. 1).

4. Place loop and 

webbing under both 

rectangular rings (Fig. 2)

See Reverse Side 

for Loop 

installation 5-6.

Cord Loop

Re-Order # Description

Belt Length Unit

909371

E-Z Release Belt with Grommets

30”-44”

Set

914119

E-Z Release Belt with Loops

30”-44”

Set

E-Z Release Belt Alarm

Safety Alarm

Отзывы: