97-12
Page 15 of 17
LIQUIDS
OIL INJECTION PUMP BLEEDING
To assure additional protection during the initial
engine break-in, 500 ml (18 imp. oz) of BOMBAR-
DIER ROTAX injection oil (P/N 413 8029 00)
should be added to fuel for the first full filling of
fuel tank.
Bleed main oil line (between tank and pump) by
loosening the bleeder screw until all air has
escaped from the line. Add injection oil as
required.
1. No air in main line
2. Bleeder screw
Bleed the small oil lines between pump and intake
manifold by running engine at idle while holding
the pump lever in fully open position.
LIQUIDS
BRAKE FLUID LEVEL
Check brake fluid in reservoir for proper level.
Add recommended brake fluid as required.
1. Fluid level window
A22C0CA
1
2
-
CAUTION
Use only (DOT 4) brake fluid from a sealed
container. Do not store or use a partial bottle
of brake fluid.
A06G1OA
1