Table 4
The Vectometer shows different flow rate (in mm
3
per minute) according to the lubricant flow rate and the working frequency of the micropump.
Setting
[mm
3
/stroke] Micropump working frequency [stroke/minute]
2,5
6
8,5
10
20
30
60
90
120
150
180
3
7,5
18
25,5
30
60
90
180
270
360
450
540
5
12,5
30
42,5
50
100
150
300
450
600
750
900
10
25
60
85
100
200
300
600
900
1 200
1 500
1 800
15
37,5
90
127,5
150
300
450
900
1 350
1 800
2 250
2 700
20
50
120
170
200
400
600
1 200
1 800
2 400
3 000
3 600
25
62,5
150
212,5
250
500
750
1 500
2 250
3 000
3 750
4 500
30
75
180
255
300
600
900
1 800
2 700
3 600
4 500
5 400
45
112,5
270
382,5
450
900
1 350
2 700
4 050
5 400
6 750
8 100
60
150
360
510
600
1 200
1 800
3 600
5 400
7 200
9 000
10 800
90
225
540
765
900
1 800
2 700
5 400
8 100
10 800
13 500
16 200
32