16
SKF TKSA 20
3.7 Measuring sequence
During the measuring cycle the shafts are rotated
through 180 degrees. Any relative movement of
the laser lines during this
rotation indicates some sort of misalignment. The
logic circuitry within the tool will translate this
movement to misalignment figures and advise on
how to correct it. A circle symbol on the display
will help, indicating the required position of the
measuring units during each step (fig. 16).
As described earlier (chapter 1.3) we use the
analogy of a clock to describe the different
positions.
Fig. 16.
Display guides you to the
9 o’clock position
a) Adjust the measuring units to the 9 o’clock
position with the aid of the spirit levels (fig.
17).
b) Confirm the measurement by pressing
Fig. 17. Adjust to the 9 o’clock position
c) Follow the circle symbol on the display and
rotate the measuring units to the 3 o’clock
position (fig. 18).
d) Confirm the measurement by pressing
Note!
By pressing the “previous” button
, you will
reverse the process in order to repeat any of
the measurement steps or to adjust any of the
machine dimensions
Fig. 18. Rotate to the 3 o’clock position