8. Displaying Temperatures
1. Press
C
•
F
•
K
to select the correct temperature scale.
2. Hold or attach the thermocouple(s) to the measurement location.
The temperature reading appears in the primary display.
3. Press
T
1
T
2
T
1
-
T
2
to toggle between showing the T1, T2 and
T1-T2 readings in the primary or secondary display.
Note:
The display shows “- - - -” when a thermocouple is not connected.
The display shows
OL
(Off Limit) when the temperature being measured
is outside the thermocouple’s measurement range.
9. Freezing the readings
1. Press
HOLD
to freeze the readings on the display .
The display shows
HOLD
.
2. Press
T
1
T
2
T
1
-
T
2
to toggle showing the T1, T2 or T1-T2 readings
in the primary or secondary display.
3. Press
HOLD
again to turn off the HOLD function.
10. Viewing the MAX, MIN, and AVG Readings
1. Press
MAX
MIN
to step through the maximum (MAX), minimum (MIN), or
the average (AVG) readings. The elapsed time since entering
MAX, MIN mode, or the time at which the minimum or maximum
occurred appears on the display.
2. Press
MAX
MIN
button for 3 seconds to exit MAX, MIN and AVG mode.
11. Replacing the Batteries
1. Turn off the thermometer.
2. Remove the screw and open the battery door.
3. Insert 3
™
new LR03 batteries.
4. Close the battery door and tighten the screw.