4. Technical data
4
- 39 -
951-171-049
Version 02
4.2 Technical data SSVD/SSVD-E
SSVD
SSVD-E
6
4
2
1
3
5
MADE IN XXXXXXX
XXXXXXX
LINCOLN
An SKF Group Brand
6
4
2
1
3
5
MADE IN XXXXXXX
XXXXXXX
LINCOLN
An SKF Group Brand
Maximum operating pressure
bar
350
350
Minimum operating pressure
bar
20
20
2)
Max. differential pressure between 2 outlets
bar
100
100
Number of outlets
6-22
6-22
Installation position
any
any
1)
Inlet thread
G1/8
G1/8
Outlet thread
M10 x 1
M10 x 1
Connectable lubrication lines
mm
Ø 4 | Ø 6
Ø 4 | Ø 6
2)
Metering volume per stroke and outlet
The metering volume is adjusted via metering screws and amounts to a
maximum of 1.8 cm³ per stroke
Possible material versions
Steel, black zinc-coated
Steel, chemically nickel-coated
Steel, black zinc-coated
3)
Function monitoring
K | KA | KN | N | NP | KS
Suitable lubrication grease consistencies
Lubrication greases up to and including NLGI 2
Suitable lubrication oil viscosities
Lubrication oils of at least 40 mm²/s at ambient temperature
4)
Ambient temperature range without electrical component
°C
-25 to + 70
-25 to + 70
4)
Ambient temperature range with electrical component
see Technical data of the respective electrical component
1)
Installation position limited by the emergency lubrication fitting.
2)
When using indicator pins, the output volume of the outlets equipped with indicator pins is reduced by about 10%.
3)
Also see chapter Function monitoring options
4)
The stated ambient temperature range assumes the transportability of the lubricant applied and the use of fittings and lubrication lines suitable for the
respective existing ambient temperature.
5)
The maximum differential pressure must not be exceeded and can be reduced by selecting the right length and diametre of the line.
Содержание SSV 10