4. Aim sensor at centre of selected belt span.
Tap or pluck the belt. The meter will beep
once to indicate that a measurement was taken.
5. Display window will show frequency result.
6. Press to toggle to newton.
7. Press to toggle to pounds.
Note: Pressing the same key a second time will return display to the hertz value.
8. Re-adjust belt tension and repeat measurement until target tension results are attained.
MEM 1
MEM 2
MEM 3
To recall stored span and mass data simply press , or .