10
3.5 Charging batteries
Do not charge batteries with the sensor head attached to the meter. Do not attempt to use the
meter while batteries are being charged. Damage to the optical sensor could result.
The SKF Belt Frequency Meter is compatible with user supplied rechargeable batteries and
charging unit. A convenient 3,5 mm, positive center charging socket is located on the bottom end
of the meter body adjacent to the sensor cable plug-in port.
Batteries: 1 300 mAh minimum (user supplied)
Charging unit: 12 to 15 volt DC output (user supplied)
Connection: 3,5 mm positive tip mini plug/socket
The built in circuit of the meter controls the charging current. Charging current is internally
limited to 100 mA. Charging time is typically 12 to 14 hours for a full charge.
You may turn the unit on while charging. The meter’s software will then signal that the batteries
are charging. The display window will flash an array of zeros, starting with only one and pro-
gressing to four. There will be an audible signal of four 'beeps' as the display charges.
Suitable rechargeable batteries and charger may be obtained directly from IDS.