SKF LINCOLN 1440CLR Скачать руководство пользователя страница 25

Special limited 5 year warranty 

limited oil meters, limited fluid control 

valves, aod (air-operated diaphragm 

pumps)

Lincoln warrants the 712 series control 

valves, 912 series lube meters, electronic 

lube meters (980, 981, 982 series), our uni-

versal inline digital meters (812/813  

series), and our AOD pump offering to be 

free from defects in material and workman-

ship for five (5) years following the date of 

purchase . If either is determined to be  

defective by Lincoln, in its sole discretion, 

during the warranty period, they will be  

repaired or replaced, at Lincoln’s discretion, 

without charge .

Special DEF (diesel exhaust fluid) limited 

warranty

DEF products are warranted to be free from 

defects in material and workmanship for a 

period of one (1) year following the date of 

purchase . The following exceptions to the 

standard warranty period are in effect:

•  85700-30/85700-50 DEF hose reels 

(bare reel only),

277251/277252 AC DEF pumps, and 

277256 and 277257 DEF meters are war-

ranted for two (2) years from date of 

purchase .

•  85623 DEF AOD  

(air operated diaphragm) pumps 

are covered under the standard five (5) 

year AOD pump warranty .  

If either is determined to be defective by Lin-

coln, in its sole discretion, during the war-

ranty period, they will be repaired or  

replaced, at Lincoln’s discretion, without 

charge .

Lincoln Industrial contact information

To find Lincoln Industrial’s nearest service 

center call the following number;

customer service 314-679-4200

(international number 01-314-679-4200)

or you may also use our website

www .lincolnindustrial .com

25

Содержание LINCOLN 1440CLR

Страница 1: ...Date of issue May 2015 Form number 404179C Section D7 Page 64C PowerLuber grease gun Model 1440CLR series D...

Страница 2: ...ructions for battery and charger 7 Electrical safety 9 Tool use and care 10 General description 11 Inspection 11 Operation 12 Charger operation 15 Important charging notes 16 Exploded views 17 Service...

Страница 3: ...perating a power tool out doors use an extension cord suit able for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock 2 6 If operating a power tool in a damp locati...

Страница 4: ...er tool repaired before use Many accidents are caused by pooly maintained power tools 4 6 Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely...

Страница 5: ...n marketed as high temperature because it must maintain their lubricating properties in hot areas but the lu bricants may be flammable if the temperature is too high Please read all warnings on lubri...

Страница 6: ...ibration emission values stated in the technical data and the declara tion of conformity have been measured in accordance with a standard test method provided by EN 60745 and may be used for comparing...

Страница 7: ...resent at charger terminals Failure to comply may result in serious injury or death D A N G E R Protecting the environment Separate collection This product must not be disposed of with normal househol...

Страница 8: ...ediately Do not attempt to repair power cord 4 Make sure cord is located so that it will not be stepped on tripped over or otherwise subjected to damage or stress 5 Do not use an extension cord unless...

Страница 9: ...lead to deterioration of the storage battery 11 Do not charge battery pack when the tem perature is below 32 F 0 C or above 104 F 40 C This is very important for proper operation 12 Do not incinerate...

Страница 10: ...0 A Lubricant Grease Up to NLGI 2 Grease output Low output 3 8 oz min 108 g min High output 8 5 oz min 241 g min Weight 8 0 lbs 3 6 kg Accessories Battery NiCd Model 1401 Output 14 4 V DC Capacity 1...

Страница 11: ...m The PowerLuber is a positive dis placement single acting pump Thermal protector The thermal protector acts as a safeguard stopping the motor if gun is run continuously at maximum pressure Fig 1 2 13...

Страница 12: ...battery when this happens Prime the PowerLuber after each refill or grease cartridge change Prime the gun before using it to lubricate grease points To prime operate the gun until grease flows from th...

Страница 13: ...rtridge from container tube To fill the gun from bulk container 1 Remove pump assembly from grease tube assembly 2 Pack lubricant into cavity of the pump assembly 3 Insert the open end of the grease t...

Страница 14: ...8 Push the follower rod into the grease tube assembly Fig 4 7 To fill the gun with a filler pump 1 Engage the follower rod with the follower by rotating the follower handle 2 Insert the gun vent bulk...

Страница 15: ...be used at this time 4 The battery pack may be left on the trickle charge until you are ready to use 5 Disconnect charger from power source when not in use Charge indicator LEDs The charger is designe...

Страница 16: ...tained if the battery pack is charged when the air temperature is between 65 and 75 F 18 and 24 C Do not charge the battery pack in an air temperature below 32 F 0 C or above 105 F 40 5 C This is impo...

Страница 17: ...s or cracks return to a service center for recycling C A U T I O N Charger troubleshooting If the battery pack does not charge properly 1 Check current at receptacle by plugging in a lamp or other app...

Страница 18: ...Fig IPB1 1 2 3 3 3 2 3 1 4 5 6 7 9 11 13 20 21 22 17 14 12 15 16 18 10 8 18...

Страница 19: ...4 4V 1401 1 14 Packing 34793 1 15 Follower assembly 93499 1 16 Trigger 286095 1 17 Clear grease tube assembly 1100CLR 1 18 Terminal assembly 286096 1 19 NS 20 Handle 286090 1 21 Follower rod 286091 1...

Страница 20: ...42 37 36 2 36 1 32 30 31 1 33 1 33 2 34 1 34 3 41 2 34 3 41 2 32 1 32 2 32 3 32 4 32 5 32 6 32 7 32 8 32 9 30 36 1 36 1 37 36 2 37 36 2 30 4 30 1 30 2 30 3 Assembly note Seal lips on seal 37 must be p...

Страница 21: ...ear set kit 286286 32 1 Motor gear 1 32 2 Gear planet 1st stage 3 32 3 Carrier 1st stage 1 32 4 Gear ring 1st stage 1 32 5 Gear planet 2nd stage 4 32 6 Carrier 2nd stage 1 32 7 Gear ring 2nd stage 1 3...

Страница 22: ...functioning Remove ball check 19 clean and inspect ball seat area PowerLuber continues to lose prime Air may be trapped in several locations in container after bulk filling Empty grease tube assembly...

Страница 23: ...oltage Directive2014 32 EC We declare that the model of the PowerLuber Grease Gun 1400 1442 1442E 1444 1444E in the version supplied by us complies with the provision of the above mentioned directive...

Страница 24: ...fered as required In no event shall Lincoln be liable for incidental or consequential damages Lincoln s liability for any claim for loss or damages arising out of the sale resale or use of any Lincoln...

Страница 25: ...free from defects in material and workmanship for a period of one 1 year following the date of purchase The following exceptions to the standard warranty period are in effect 85700 30 85700 50 DEF hos...

Страница 26: ...This page left intentionally blank 26...

Страница 27: ...This page left intentionally blank 27...

Страница 28: ...ng operational and energy efficiency and reducing total cost of ownership These competence areas include bearings and units seals lubrication systems mechatronics and a wide range of services from 3 D...

Отзывы: