X
X
Y
X
Y
X
Dimension X is to be
9 mm or more.
Target
Attachment plate
Probe
Target
Dimension X is to be
9 mm or more.
Dimension Y is to be
15 mm or more.
Installation example 1 (most recommended)
Installation example 2 (recommended)
Target
Target
Target
Target
After constructing as
shown in installation
example 2, the area shown
by the shaded line in the
illustration is filled with
resin or other insulating
material.
If dimension X is less than
9 mm, it will be affected by
the attachment plate.
If dimension Y is less than
15 mm, it will be affected
by the attachment plate.
If the attachment plate
around the sensor tip is
chamfered, it will be
affected by the attachment
plate.
If the target and the sensor
tip are not parallel (dimen-
sion X1 and X2 are not the
same), it will affect the
reading.
If dimension X is 0,25 mm
or less, measurement will
not be possible. The area
0,25 mm or less is a
non-sensitive area.
Installation example 3 (recommended)
Installation example 4
Installation example 5
Installation example 6
Installation example 7
Installation example 8
X2
X1
Install example 1 to 3
Install example 4 to 6
Install example 7
Output, V
Non-sensitive area
(be careful of this area)
Gap, [mm]
The characteristics of output (V) and gap [mm]
Target
Target
Recommended
For further information, refer Appendix B:
Influences on the Output Characteristic.
System characteristic affected